23 U109645
INSTALLATION
Check that the appliance is electrically safe when you have finished.
Australia
View from the rear of the cooker
Electrical Connection
This appliance must be installed by a qualified
electrician to comply with the relevant regulations (in
particular AS/NZS 60335.2.6:2002), and also the local
electricity supply company requirements.
Ensure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data plate
affixed to the cooker.
The cooker is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit
breaker that completely disconnects the appliance from
the mains, with a minimum contact break distance of
3mm.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance must be connected to an efficient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations.
Earthing is a safety measure required by law, and
must be performed with particular care by a qualified
technician, who must also check that the electricity
supply characteristics are correct.
The cable size used should be suitable for the appliance
load and in accordance with local regulations. Please note
that the maximum cable sizes are 6mm
2
for the screw
terminals.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type.
You may need to move the links to suit your connection
type. Check that the links are correctly fitted and that the
terminal screws are tight. Secure the mains cable using
the cable clamp.
The single phase connection is shown above.
Check that the links are correctly fitted and that the
terminal screws are tight.
Secure the mains cable using the cable clamp:
Summary of Contents for Elan U109645 - 02
Page 28: ...U109645 28 Australia Circuit Diagram...
Page 31: ...31 109645 Australia...
Page 32: ......