01
Hardware over coil
Use of unsuitable pan material
Re-set required
Defective coil
Use suitable pan.
Switch unit off for 10 seconds, then on
Engineer required
02
No inductor coil
current
Re-set unit
Inductor coil connection failure
Switch unit off for 10 seconds, then on
Engineer required
03
Heat sink temperature
too high
Re-set required
Air routes blocked
Air filter blocked
(requires cleaning)
Generator fans clogged
Generator fan malfunction
(due to clogging)
Generator fan malfunction
(due to electrical fault)
Generator fan blows instead of
sucks
Room temperature abnormally high
External heat source too close
Defective generator temperature
sensor
Switch unit off for 10 seconds, then on
Check below and rear of unit for potential
airflow obstruction
Check filter, it may require cleaning/replacing
Is a filter fitted? Vacuum if necessary
Engineer required
Engineer required
Engineer required
Cool down room
Move appliance away from heat source
Engineer required
04
Cooking zone
temperature too high
or remains constant
during use
Re-set required
Pan empty or too hot
Pan base distorted
Faulty temperature sensor
(constantly recording ambient)
Switch unit off for 10 seconds, then on
Check pan has not boiled dry or is empty
Allow cook zone to cool. Check/replace pan
Engineer required
05
Control failure
Re-set required
Faulty control or incorrect wiring
Switch unit off for 10 seconds, then on
Engineer required
06
Internal temperature
of generator too high
Re-set required
Refer to fault 03
Switch unit off for 10 seconds, then on
Refer to fault 03
07
Cooking zone
temperature sensor
Reset required
Faulty/malfunctioning temperature
sensor
Switch unit off for 10 seconds, then on
Engineer required
08
Mains supply failure
Re-set required
Fault with mains supply
Switch unit off for 10 seconds, then on
Engineer required
09
N/A
N/A
N/A
Code
Error
Cause
Action by user