Falcon E3903i User Instructions Download Page 7

01

Hardware over coil

Use of unsuitable pan material

Re-set required

Defective coil

Use suitable pan. 

Switch unit off for 10 seconds, then on

Engineer required

02

No inductor coil 

current

Re-set unit

Inductor coil connection failure

Switch unit off for 10 seconds, then on

Engineer required

03

Heat sink temperature 

too high

Re-set required

Air routes blocked

Air filter blocked 

(requires cleaning)

Generator fans clogged

Generator fan malfunction 

(due to clogging)

Generator fan malfunction 

(due to electrical fault)

Generator fan blows instead of

sucks

Room temperature abnormally high

External heat source too close

Defective generator temperature 

sensor

Switch unit off for 10 seconds, then on

Check below and rear of unit for potential 

airflow obstruction

Check filter, it may require cleaning/replacing

Is a filter fitted? Vacuum if necessary

Engineer required

Engineer required

Engineer required

Cool down room

Move appliance away from heat source

Engineer required

04

Cooking zone 

temperature too high 

or remains constant

during use

Re-set required

Pan empty or too hot

Pan base distorted

Faulty temperature sensor

(constantly recording ambient)

Switch unit off for 10 seconds, then on

Check pan has not boiled dry or is empty

Allow cook zone to cool. Check/replace pan

Engineer required

05

Control failure

Re-set required

Faulty control or incorrect wiring

Switch unit off for 10 seconds, then on

Engineer required

06

Internal temperature

of generator too high

Re-set required

Refer to fault 03

Switch unit off for 10 seconds, then on

Refer to fault 03

07

Cooking zone 

temperature sensor

Reset required

Faulty/malfunctioning temperature

sensor

Switch unit off for 10 seconds, then on

Engineer required

08

Mains supply failure

Re-set required

Fault with mains supply

Switch unit off for 10 seconds, then on

Engineer required

09

N/A

N/A

N/A

Code

Error

Cause

Action by user

Summary of Contents for E3903i

Page 1: ...SURE ALL POT PAN BASES ARE FLAT AND CLEAN PRIOR TO USE THE AIR INTAKE FILTER MUST BE CLEANED REGULARLY TO REMOVE POTENTIAL OBSTRUCTIONS THIS APPLIANCE CAN BE USED BY PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE KNOWLEDGE PROVIDED SUCH INDIVIDUALS HAVE BEEN GIVEN INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND THAT THEY UNDERSTAND THE HAZARDS INVO...

Page 2: ...rings watches bracelets etc worn by the user could become hot when in close proximity to the cooking zone Do not place credit cards etc on the glass ceramic top as data could be wiped off Never leave the induction hob unsupervised when in use The glass ceramic top must NOT be used for storage Do not place cloths etc over appliance rear This may impede flue outlet and cause overheating of appliance...

Page 3: ...ndication i e RH rear Figure 5 Unit will not Operate Ø110mm pan If inner circle markings can be seen the pan is too small Detection will prevent cooking using this size of pan Figure 6 Unit will Operate Ø120mm pan Pan is ideal positioned centrally Inner circle markings cannot be seen Note Positioning lines are available for central positioning of pan Figure 7 Unit will not Operate Ø120mm pan Pan i...

Page 4: ...s is also liable to happen if pans are damaged e g large dents Figure 15 Pot base is bowed inward and is NOT FLAT The unit efficiency will be dramatically reduced during cooking It may not even be detected by the appliance Note This is also liable to happen if pans are damaged e g large dents Figure 16 Excessive food spillage stuck to pan base will impinge the balance the pan One side of utensil w...

Page 5: ...take filter regularly The filter is located below the body of the appliance at front and centre It can be removed by sliding out of the front Clean using hot soapy water and re fit after drying Failure to clean the filter regularly may cause problems which will not be covered by warranty The air intake filter MUST be in place during operation The glass ceramic top can be wiped clean using a damp c...

Page 6: ...e table This will provide the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or show any operational indicators Follow details in Error Code Table before calling a service engineer The symptoms may indicate a failed induction generator ERROR CODE TABLE If ...

Page 7: ...cessary Engineer required Engineer required Engineer required Cool down room Move appliance away from heat source Engineer required 04 Cooking zone temperature too high or remains constant during use Re set required Pan empty or too hot Pan base distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Allow coo...

Page 8: ...tor detects that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required 13 Mains connection error Re set required Mains voltage is too high or too low Switch unit off for 10 seconds then on Engineer required 14 Mains connection error Re set required Mains voltage is too high or too low Switch unit off for 10 seconds then on Engineer required 15 Coil...

Reviews: