Falcon E3903i User Instructions Download Page 6

SECTION 5 - TROUBLESHOOTING

If a fault occurs during use, an error code will be

displayed in a series of  flashes.

These correspond to the numbers in the code column of

the following table.

For example, 6 short flashes followed by an extended

flash would indicate error code 06

(Generator internal

temperature too high).

The codes are provided to diagnose possible faults and

the action required to remedy any such condition.

Note: Most faults can be rectified by simply

switching the unit off for 10 seconds. After this time,

turn the power back on at mains supply.

If the fault continues to occur after this action then

please refer to the table. This will provide the

solution to rectify the condition. 

SUPPLY PROTECTION DEVICE

The appliance is fitted with a miniature circuit breaker

(MCB)

as additional protection against over current.

If unit fails to operate or show any operational indicators,

Follow details in Error Code Table before calling a

service engineer. The symptoms may indicate a failed

induction generator.

ERROR CODE TABLE

If any fault occurs during use, an error code

corresponding to the details in the table will be displayed

as a series of flashes.

For example, 6 short flashes followed by a long flash

would indicate error code 06.

The codes will help determine unit faults and the table

lists actions required to remedy any such fault.

Note

: most errors will be rectified by switching  unit off at

mains supply for 10 seconds and switching supply back

on.

Summary of Contents for E3903i

Page 1: ...SURE ALL POT PAN BASES ARE FLAT AND CLEAN PRIOR TO USE THE AIR INTAKE FILTER MUST BE CLEANED REGULARLY TO REMOVE POTENTIAL OBSTRUCTIONS THIS APPLIANCE CAN BE USED BY PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE KNOWLEDGE PROVIDED SUCH INDIVIDUALS HAVE BEEN GIVEN INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND THAT THEY UNDERSTAND THE HAZARDS INVO...

Page 2: ...rings watches bracelets etc worn by the user could become hot when in close proximity to the cooking zone Do not place credit cards etc on the glass ceramic top as data could be wiped off Never leave the induction hob unsupervised when in use The glass ceramic top must NOT be used for storage Do not place cloths etc over appliance rear This may impede flue outlet and cause overheating of appliance...

Page 3: ...ndication i e RH rear Figure 5 Unit will not Operate Ø110mm pan If inner circle markings can be seen the pan is too small Detection will prevent cooking using this size of pan Figure 6 Unit will Operate Ø120mm pan Pan is ideal positioned centrally Inner circle markings cannot be seen Note Positioning lines are available for central positioning of pan Figure 7 Unit will not Operate Ø120mm pan Pan i...

Page 4: ...s is also liable to happen if pans are damaged e g large dents Figure 15 Pot base is bowed inward and is NOT FLAT The unit efficiency will be dramatically reduced during cooking It may not even be detected by the appliance Note This is also liable to happen if pans are damaged e g large dents Figure 16 Excessive food spillage stuck to pan base will impinge the balance the pan One side of utensil w...

Page 5: ...take filter regularly The filter is located below the body of the appliance at front and centre It can be removed by sliding out of the front Clean using hot soapy water and re fit after drying Failure to clean the filter regularly may cause problems which will not be covered by warranty The air intake filter MUST be in place during operation The glass ceramic top can be wiped clean using a damp c...

Page 6: ...e table This will provide the solution to rectify the condition SUPPLY PROTECTION DEVICE The appliance is fitted with a miniature circuit breaker MCB as additional protection against over current If unit fails to operate or show any operational indicators Follow details in Error Code Table before calling a service engineer The symptoms may indicate a failed induction generator ERROR CODE TABLE If ...

Page 7: ...cessary Engineer required Engineer required Engineer required Cool down room Move appliance away from heat source Engineer required 04 Cooking zone temperature too high or remains constant during use Re set required Pan empty or too hot Pan base distorted Faulty temperature sensor constantly recording ambient Switch unit off for 10 seconds then on Check pan has not boiled dry or is empty Allow coo...

Page 8: ...tor detects that current does not reflect what controls require Switch unit off for 10 seconds then on Engineer required 13 Mains connection error Re set required Mains voltage is too high or too low Switch unit off for 10 seconds then on Engineer required 14 Mains connection error Re set required Mains voltage is too high or too low Switch unit off for 10 seconds then on Engineer required 15 Coil...

Reviews: