SERVICING - WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
27
Natural Gas at 20mbar
The 95 jet in burner A is counter-bored and is different to
the non- counter-bored 95 jet in the conversion kit
Burner
Burner rings
A
95
39
original ring
B
120
54
original ring
C
165
96
original ring
LP Gas - Butane at 28-30 or Propane at 37mbar
Use the non counter-bored 95 jet in the conversion kit for
burner C
Burner
Burner rings
A
64
32
original ring
B
82
40
original ring
C
107
57
Large ring in
conversion kit
Reassembly
LP Gas
Centre burner
Large Ring
If you are converting to
LP Gas the burner ring in
the centre burner must be
changed for the large ring in
the conversion kit.
Screw in the hexagon headed venturi but to make fitting
the outer burners easier do not fully tighten yet.
Save the original brass ring with the removed orifices
and bypass screws.
the centre burner