24
c) Mark off 300mm from the RH side of the unit to
indicate the centre line for the bracket.
d) Remove the unit.
e) Mark off 595mm to locate the front edge of the lower
bracket. Fix bracket to floor.
f) Measure the height from floor level to the top edge
of the rear channel. Add 3mm to this dimension and
assemble the stability bracket to this height (i.e. from
floor level to underside of top member).
Gas Connection
The Gas supply needs to terminate with a down facing
bayonet. The rear cover boxes limit the position of the
supply point.
view from the rear
A
position for gas supply connector
B
appliance gas inlet
Because the height of the cooker can be adjusted and
each connection is different it is difficult to give precise
dimensions. Ideally the house supply bayonet should
be in the shaded area shown in the diagram. Although
a 900mm hose can be used, a 1250mm hose will allow
slightly more flexibility in the positioning of the bayonet
and make moving the cooker easier. The hose should
be fitted so that both inlet and outlet connections are
vertical so that the hose hangs downwards.
The hose should be fitted so that both inlet and
outlet connections are vertical so that the hose hangs
downwards in a ‘U’ shape.
For Natural Gas the flexible hose must be in accordance
with B.S.669.
For LP Gas it should be capable of 50mbar pressure, 70C
temperature rise and carry a red stripe, band or label.
If in doubt contact, your supplier.
Screw connect the threaded end of the hose into the gas
inlet in the underside of the connector block on the back
of the cooker.
After completing the gas connection, check the cooker
is gas sound with a pressure test. When checking for gas
leaks do not use washing up liquid - this can corrode.
Use a product specifically manufactured for leak
detection.
Pressure testing
The gas pressure can be measured at the pressure test
point on the gas connection block. Turn and light one of
the hotplate burners.
For Natural Gas the pressure should be 20mbar.
For Propane the pressure should be 37mbar.
Reassemble burner top, making sure it is reassembled in
the correct way on the burner body.
Electrical Connection
This appliance must be installed by a qualified electrician
to comply with the relevant regulations and also the
local electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker,
through a suitable cooker control unit incorporating
a double pole switch having a contact separation
of at least 3mm in all poles. This cooker must not be
connected to an ordinary domestic power point.
The total electrical load of the appliance is approximately
7.2kW. The cable size used should be suitable for this
load and comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for your
electrical supply type.
Check that the links are correctly fitted and
that the terminal screws are tight.
Secure the mains cable using the cable clamp.