Lumina 17
House setup
21
Controlpart
Setting indicating if the controllable part of the ventilation control consists of linear
controllable fans (
LINEAIR
) or modulating on/off fans (
RELAY
).
Type
Setting indicating which type of ventilation control is used.
•
Direct
•
ProFlow direct
•
ProFlow end station
•
EasyFlow
Analog extra switching*
Setting indicating the number of analog (linear controllable) fans that you want to activate
as extra fans in the controllable part.
Relay extra switching*
Setting indicating the number of on/off fans that you want to activate as extra fans in the
controllable part.
Vortex damper in use
Setting indicating if vortex damper control is used. A vortex damper is always controlled
analog. There is one vortex damper control per extra switched fan.
Natural ventilation
Setting indicating if natural ventilation is used/present in the house
Number of air inlets
Setting indicating the number of air inlets to be used.
Extra inlet
Setting indicating if there is an extra air inlet in the house.
Number of stages Combi
Setting indicating the number of stages to be used in the combi-table.
Number of relays
Setting indicating the number of relays you want to use for the extra fans.
HOUSE SETUP
tab page
Clocks
Registration
Setting indicating if registration inputs are used.
Use clocks
Setting indicating if clocks are used.
Time clock
Settings if time clock is used.
Feed clock
Setting indicating if feed clock is used.