24
USAGE
EN
WARNING!
After water reservoir removed
,
to reinstate the operation, it
takes about 3 minutes to start the unit again for protection
purpose. To scrub off protection time, you may remove
plug from power socket to restart the unit.
Automatic defrosting
Overflow protection
When condensed water is full, buzzer will alarm 10 times
(about 5 seconds). Whilst, the symbol of water full is
exhibited on LCD screen, all other symbols turn to orange
and the appliance stops to work. The water reservoir must
be removed to empty and reinstalled before the unit
operates again. The interval of dehumidifying lasts about 3
minutes because of the compressor’s protection.
Processions of abnormal
compressor
During the operation, any malfunction forced compressor
failed, resulting compressor shut off, it takes 3 minutes to
rework for protection period.
A working cycle: When the appliance work in low
temperature, frost will be produced on the surface of
evaporator. To ensure the appliance performs well, the
automatic defrost function is designed with the appliance.
a
)
When room temperature dropped down to 16
℃
or lower,
which detected by temperature sensor to generate
compressor works 25 minutes on dehumidifying then cut
off, fan blower keeps running 7 minutes to defrost in a
cycle.
b
)
When defrost
,
Symbol of defrost displayed on LCD,
and the symbol of dehumidification goes out.
c
)
When defrost
,
Symbol of defrost displayed on LCD, the
compressor is shut off, fan runs at high speed.