30iE - v1111 - Installation/Operation - (42/48)
PAR30 to 35
Axis assigned to each output.
PAR30 corresponds to O1 (home) and PAR35 to O6
(end).
0.- Output not active.
1. Output controlled by X axis.
2. Output controlled by Y axis.
3. Output controlled by Z axis.
PAR40 to 45
Position where each output O1 through O6 is activated.
PAR40 for O1, PAR45
for O6.
PAR53
Select the number of decimals to be displayed.
Possible values:
0.0 to 6.6 .
The first digit corresponds to the number of decimals to be displayed in mm and the
second digit to the number of decimals in inches.
When selecting a “0” value or a value greater than the number of decimals of
PAR01
it will display the factory set number of decimals.
Note:
It has no effect on rotary axes.
PAR65
It enables various functions of the dro.
Digit
8
1= To enter the tool length.
7
1= To enter the tool diameter.
6
1= To compensate for tool radius.
5
1= to edit or preset the axes.
4
1 = To deactivate the digital outputs of the DRO.
3
1 = Enables the buzzer. It beeps when pressing any key.
2
Enables this key (linear and bolt-hole drilling, etc.)
1
It enables this key.