30iE - v1111 - Installation/Operation - (38/48)
1
Detect feedback speed alarm when exceeding 200Khz (60m/min with a resolution of
1µm). Not applicable to a rotary axis.
Possible values: 0 (alarms off) and "1" (alarms on).
Factory-set (default) values: 0
Feedback and feedrate alarms are shown with (. . . . . . . .) at the display.
The errors may be cleared by pressing this key.
PAR09
Linear compensation of a machine axis.
Independent for each linear axis.
Numeric value within ±99.999 millimeters per meter.
Factory setting: 0.
Notes:
Even when selecting the d isplay in inch es, this value MUST ALWAYS BE IN
MILLIMETERS.
1 inch = 25.4 mm
When a rotary axis, the setting of this parameter will be ignored.
PAR10
Offset of the reference point
with respect to the reference zero of the scale,
independent for each axis.
Usually, the machine reference zero (reference mark of the linear encoder) does not
coincide with the absolute zero to be used.
Therefore, when using standard Io's, this para meter must be assigned the value of
the distance from the machine zero point to the feedback reference point.
Numeric value in resolution units for each axis.
Factory setting: 0.
This value will be in mm or inches depending on whether the INCH LED is off or on.
PAR11
Personalize.
Digit
8
Not being used. Must be set to "0".
7
Operate always in mm.
6
Operate always in inches.
5
Do not display "Fagor DRO" on power-up.
4
If =0, normal zero setting and coordinate presetting (factory set)
If =1, quick zeroing of the position value displayed on each axis.
3
If =1, allow the selection of the work plane for linear or bolt-hole drilling.
2
Not being used; it must be set to "0".