background image

 

 

20 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ip

2

1

1

1

1

1

n

m

g

n

m

Cc2

vi

ve

g

A1

A2

Z-213007

rs

b

r

n

m

Cc1

vi

ve

g

A1

A2

rs

ve

m

n

a

b1

a1

Cp

Z-203062

r

Ct

am

a

g

ve

a

g

A1
A2

Z-213007

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

1

1

1

230 V - 3 ~

a

am

/v

e

n

g

m

a

T S R

1

1

1

230 V - 1N ~

a

g

m

n

am

/v

e

n

g

m

a

N

R

400 V - 3N ~

a

g

m

n

am

/v

e

n

g

m

a

N T S R

1

1

1

1

1

1

2

1

1

na

b

ve

na

rs

b

rs

m

rs

rs

rs

n

a

Com

Com

6 seg.

180 seg.

M5

M4

M3

M2

M1

r

ve

L1

1

1

1

3

3

3

1
1

1

g

ve

a

3

3

3

3

3

3

IG

2 1

ve

a

r

m

na

na

3a

2a

1a

3

2

1

1

1

1

1

1

r

Z-

20

30

23

P1

3

1

2

n

m

1

rs

vi

vi

rs

ve

V1

ve

Z-203009

Z-243047

Z-243046

TMC

TMT

R-693056

Z-213003

R-253044

60HZ    Z-258412

Z-701135

Z-683087

NC

Z-273060

Z-273060

ºF

ºF

Z-243048

Q-578006

Q-578006

ESQUEMA TEORICO                                Z-263005

LEYENDA                                                  Z-243051

INDICADOR DE COMPONENTES            Z-713034

Q-578006

rs

ve

Z-203014

(EGO)

2

4

1

vi

na

rs

Tc

Det.

Ds

am/ve

am/ve

a

g

Rt

MB

C

b

n

am/ve

1

1

1

1

1

1

1

1

1

1

1

1

vi

vi Z-213014

Z-208903

Z-20890

4

50HZ  B-A   Z-201011

60HZ    W   Z-203511

V-32130

Z-203601

b

ve

TSC

Z-203014

(EGO)

2

4

1

rs b

Tstp

4

1

4

4

4

1

1

1

Z-203014

(EGO)

2
4
1

am

na

g

Tt

cortar

TMC

TSC

TC

Rc

m

rs

am/ve

r

b

g

n

ºF     W      Z-241703

1

4

4

4

4

4

3

3

3

3

3

4

4

4

4

rs

b

rs

b

4

4

4

4

4

4

Z-208436

FI-72W

Z263006000    HC-17897-2

Z-203080

ST

1

2

na

 L2

n

ve

rs

LAMPARA

Summary of Contents for FI - 48 W

Page 1: ...GENERAL INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE INSTRUCCIONES GENERALES PARA INSTALACI N USO Y MANTENIMIENTO UNDERCOUNTER DISHWASHER Models FI 48 W FI 64 W FI 72 W Z 208432 01...

Page 2: ...1...

Page 3: ..._________________6 2 7 ELECTRICAL CONNECTION _______________________________________________7 3 INSTALLATION CHECKLIST ___________________________________________________8 4 USE ______________________...

Page 4: ...Flow rinse pressure 15 25 psi Total Time Seconds 2 settings 120 180 Wash Pump Motor Dimensions Shipping Motor hp 1 hp Width 24 1 4 616 mm Depth 27 1 2 698 mm Temperatures Height 38 1 2 978 mm Wash 15...

Page 5: ...ures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 12 318mm Rinse 190 F 88 C Rack 20 x 20 500mm x 500mm Shipping weight 160 lbs 73 kg Shipping volume cu ft 15 TECHNICAL SPECIFICATION...

Page 6: ...peratures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 16 420mm Rinse 190 F 88 C Rack 20 x 20 500mm x 500mm Shipping weight 174 lbs 79 kg Shipping volume cu ft 29 TECHNICAL SPECIFIC...

Page 7: ...with the carrier In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in writte...

Page 8: ...and adjusting the height of the appliance is done by turning the leveling stands to the desire height Ensure that the unit is level before making any connections Fig 2 Fig 2 2 5 WATER INSTALLATION Wa...

Page 9: ...an obstruction prior to connecting to the machine Use only the supplied hoses 3 4 Female hose connector at the water connections Failure to do so may result in damage to the solenoid valve threads and...

Page 10: ...n guidelines and data plate The machine must be grounded WARNING Electrical Shock Hazard It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure t...

Page 11: ...valve open q Is the incoming water supply at 20 40 psi q Has been installed with the supplied water hose q Is the water hose not kinked q Has the incoming water supply been flushed for debris q Is th...

Page 12: ...HE ROUND SCRAP BASKET ONLY THE TUBE When the working day is complete set selector knob 1 to the 0 setting Fig 7 FI 64 W FI 72 W Set the selector knob 1 Fig 7 to the position 90 seconds cycle or positi...

Page 13: ...ted by the manufacturer into the tub Fig 9 indicate the doser regulation range Control and maintain the level of detergent and rinse aid of the tanks Keep pipe and filters submerged Preparing the croc...

Page 14: ...do this remove the overflow tube A turn scrap basket counterclockwise and lift F Replace the clean scrap basket F by putting the groves into the slots and turning clockwise Fig 13 If the machine is n...

Page 15: ...tch Ip or the door relay Rp Faulty fill pressure switch P1 Verify position change 1 2 1 3 to pressure switch Possibly stuck Dishwasher will NOT FILL after the door is closed Power ON light L1 is illum...

Page 16: ...e with a calibrated thermometer Replace temperature gauge if necessary Misadjusted faulty thermostat Tc Verify operation and setting of thermostat replace if necessary If thermostat is not receiving v...

Page 17: ...re switch P2 Verify position changes from 1 3 to 1 2 Machine temperatures or pressure may not be to specification Verify that the water pressure is at a min of 20psi and max 60 psi The water temperatu...

Page 18: ...6 5a TSC FI 48 W V M3 M Ds Det m m ve b M4 g m rs L2 r rs a g 0 180 X X 1 1a 2 2a 3 3a 4 4a 5 5a 6 6a 7 7a 8 8a X X X X X X X X X X X X X I G I G 180 0 160s Rinse Wash M5 M3 M2 M1 Termo Stop M4 180sec...

Page 19: ...4 4a 5 5a 6 6a 7 7a 8 8a X X X X 90 X X X X X X X X X I G I G 90 180 0 160s Fast got to 90sec Progr Rinse Wash M5 M3 M2 M1 90sec Program Termo Stop M4 180sec 90s 5s 15s 2 Z 258439000 HC 17993 Cp Cp 2...

Page 20: ...1 160s Fast got to 90sec Progr Rinse Wash M5 M3 M2 M1 90sec Program Termo Stop M4 180sec 90s 5s 15s 2 X X X X I G 90 X 3a 3 2a 2 1a 1 180 0 I G 90 180 0 Cp Cp 208 220 240 V 3Ph R S T Ct Cc1 Cc2 Rt Rc...

Page 21: ...Z 273060 W ESQUEMA TEORICO FI 48W Z 228444 LEYENDA Z 243051 INDICADOR DE COMPONENTES Z 713034 a am v e g n m a 380 415 V 3N N T S R NC NC A2 A1 n n a ve a vi CC1 Z 743009 R S T N a m g n am ve 220 240...

Page 22: ...vi rs rs n a Com Com 6 seg 180 seg M5 M4 M3 M2 M1 1 2 3 4 5 6 7 8 1a 2a 3a 4a 5a 6a 7a 8a vi b am na na m r n rs g g a ve 1 2 IG r ve L1 1 1 1 rs ve V 3 3 3 1 1 1 g ve a 4 3 3 3 3 3 3 vi vi Z 203009 Z...

Page 23: ...m 1 rs vi vi rs ve V1 ve Z 203009 Z 243047 Z 243046 TMC TMT R 693056 Z 213003 R 253044 60HZ Z 258412 Z 701135 Z 683087 NC Z 273060 Z 273060 F F Z 243048 Q 578006 Q 578006 ESQUEMA TEORICO Z 263005 LEY...

Page 24: ...Z203018 up to May 02 Z203023 Level pressure switch Z203511 Pump Motor 60Hz Z203601 Heating element for tank 2800W 230V Z211903 Rinsing nozzle Z213007 Contactor 230V 50 60Hz Z213014 Safety thermostat...

Page 25: ...vel pressure switch Z203511 Pump Motor 60Hz Z203601 Heating element for tank 2800W 230V Z211903 Rinsing nozzle Z213007 Contactor 230V 50 60Hz Z213014 Safety thermostat Z213033 Start button Z223001 Gen...

Page 26: ...discovered the claim In connection with all claims under this Warranty Fagor will have the right at its own expense to have its representatives inspect the Equipment at the User s premises and to requ...

Page 27: ...ICULAR PURPOSE NO OTHER WARRANTIES ARE AUTHORIZED ON BEHALF OF FAGOR UNLESS SPECIFICALLY ISSUED BY FAGOR Fagor shall have no liability for incidental or consequential losses damages or expenses loss o...

Page 28: ...Fagor Commercial Inc 6992 N W 82nd Ave Miami Fl 33166 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Reviews: