7
2.7
ELECTRICAL CONNECTION
−
To access to the electrical terminal block (R) (Fig. 1), remove the top cover (T) (Fig. 1) and the rear
panel (P) (Fig. 1). Connect the wires as shown in figure 6. Insert the power cord through the cord
holder (E) (Fig. 1) and make sure to leave enough cable to remove the electrical panel from the
front for service. Tighten the connections.
−
Leave free
≥
39” (
≥
1000 mm) of power cord from the rear to facilitate cleaning of the location of
the dishwasher.
−
Install a circuit breaker in accordance to required consumption guidelines and data plate.
−
The machine must be grounded.
WARNING: Electrical Shock Hazard
It is the personal responsibility and obligation of the customer to contact a qualified electrician to
assure that the electrical installation is adequate and is in conformance with the National Electrical
Code, ANSI / NFPA 70 – latest edition and all local codes and ordinance.
Fig.6
T
S R
N
Clear Cap
Yellow / Green
Wire
Clear Cap
Blue Wire
Gray Cap
Red Wire
Bridge
Blue Cap
White Wire
Clear Cap
Brown Wire
Brown Cap
Red Wire
Clear Cap
Red Wire
Red Cap
Red Wire
Ground
Line
Line
Note: Bridge may have a brown wire.
Clear Cap
Black Wire
White Cap
Red Wire
Line
FI-48W, FI-64W
208-220 volts/1phase
FI-64W, FI-72W
208-220-240 volts/3phase
Summary of Contents for FI - 48 W