CHEMICAL AND TABLE LIMIT SWITCH CONNECTIONS
This machine must be operated with an automatic detergent feeder and, if applicable, an automatic
chemical sanitizer feeder, including a visual means to verify that detergents and sanitizers are
delivered or a visual or audible alarm to signal if detergents and sanitizers are not available for
delivery to respective washing and sanitizing systems. Please see instructions for electrical and
plumbing connections located in this manual and in the feeder equipment manual.
Fagor does not recommend any brand name of chemicals or chemical dispensing equipment.
Contact your local chemical distributor for questions concerning these subjects.
To access to the connections terminal block, remove the top cover. See figure 7 to connect
electrically detergent and rinse feeders. To connect the table limit switch (safety end switch)
FIRST remove bridge wire between terminals 4 & 5 and then connect the switch.
Fig.7
Z312941000 Terminal block. 3 phases connection
Power cord must go through
this
TERMINAL BOX
Ground terminal