15
8.3
Electrical connection
An AUTHORISED TECHNICIAN should always carry out the appliance’s electrical
connection.
The dishwasher shall be installed in accordance with local codes, or in the
absence of local codes, installed in accordance with the applicable requirements
in the National Electrical Code, NFPA 70, Canadian Electrical Code (CEC), Part 1,
CSA C22.1, and Standard for Ventilation Control and Fire Protection of
Commercial Cooking Operations, NFPA 96.”.
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED
The manufacturer cannot accept any responsibility for damage caused from a
failure to observe grounding instructions.
Refer to the wiring diagram, the machine data plate and technical specifications for
service size requirements.
Check that the mains voltage corresponds to that indicated on the nameplate.
The power-supply cord shall be Type S, SE, SO, SOO, ST, STO, or STOO (with or
without W at the end).
The power supply cord wire size must be suitable for the rated current of the
machine (amperage load). Use copper conductors only.
The appliance must be grounded using the ground connection of the terminal block
of the appliance.
An all phase Circuit Breaker must be installed near to the appliance between the
power supply and the appliance in accordance to required consumption guidelines.
Switch the circuit breaker to “OFF” when servicing the appliance. It is
recommended that it has lockout-tagout capabilities. The manufacturer will not be
held liable for damage originated by failure to observe this requirement.
A suitable safety switch / Residual current device must be installed near the
appliance between the power supply and the appliance. The manufacturer will not
be held liable for damage originated by failure to observe this requirement.
If any faults are observed during the installation, the supplier should be notified
immediately.
When a number of appliances are installed in line, they should all be ground bonded at the point
provided for that purpose.
To access the connection strip, release the cover of the machine’s rear in the undercounter
dishwhasers and on the left lower side of the hood type dishwhasers. The power cable is connected
to the connection strip. It is also possible to change the machine configuration here.
The manufacturer will not be held liable for any personal or material damage to the
machine resulting from incorrect installation or failure to comply with the
manufacturer’s specifications.
It is the personal responsibility and obligation of the customer to contact a
qualified electrician to assure that the electrical installation is adequate.