![Fagor CNC 8060 Hardware Configuration Download Page 52](http://html1.mh-extra.com/html/fagor/cnc-8060/cnc-8060_hardware-configuration_3190792052.webp)
Hardware configuration.
CNC 8060
4.
·52·
(R
EF
: 1709)
CN6
0-10H /
C
N
60-10
HT CN6
0-10V /
CN
60-10
VT
CN60
-1
0
K.
4.6
Technical/electrical characteristics of the inputs and outputs.
4.6.1
Digital inputs.
All digital inputs are galvanically isolated up to 500 V through opto-couplers. All digital inputs
meet the standard IEC61131-2 type 1 and type 3.
4.6.2
Digital outputs.
All digital outputs are galvanically isolated up to 500 V through opto-couplers. All the digital
outputs have the following characteristics:
4.6.3
Analog outputs.
Use shielded cables connecting their meshes to the corresponding shield pin. All the analog
outputs have the following characteristics:
Characteristic.
Value.
Nominal voltage.
+24 V DC (b18 V DC and +30 V DC).
Activation level.
From +11 V DC on and between 2.1 mA and 2.6
mA.
Deactivation level.
Under +10 V DC or 1.5 mA.
Characteristic.
Value.
Nominal voltage.
+24 V DC (b18 V DC and +30 V DC).
Output voltage.
2 V less than the supply voltage.
Maximum output current.
500 mA per output.
Minimum cycle on.
Pins LO1 LO2: 25 µs.
Rest of pins: 75 µs.
For the PWM and synchronized switching, only pins LO1 or LO2 may be used. Depending on the input
receiving the PWM pulse and the cable, an external load resistor (at least 10% of rated current; if 24
V, 470
/ 2 W) improves signal quality and noise immunity.
Characteristic.
Value.
Command voltage within range.
±10 V.
Resolution.
16 bits.
Minimum impedance of the connected device.
10 k
.
Maximum cable length (unshielded).
75 mm.
Summary of Contents for CNC 8060
Page 1: ...Ref 1709 8060 CNC Hardware configuration...
Page 8: ...BLANK PAGE 8...
Page 10: ...BLANK PAGE 10...
Page 12: ...BLANK PAGE 12...
Page 16: ...BLANK PAGE 16...
Page 18: ...BLANK PAGE 18...
Page 20: ...BLANK PAGE 20...
Page 22: ...Hardware configuration CNC 8060 1 22 REF 1709 PREVIOUS INFORMATION...
Page 30: ...Hardware configuration CNC 8060 3 30 REF 1709 CENTRAL UNIT CPU ENCLOSURE...
Page 86: ...Hardware configuration CNC 8060 6 86 REF 1709 OP PANEL 329...
Page 98: ...Hardware configuration CNC 8060 7 98 REF 1709 OP PANEL OP PANEL SPDL RATE...
Page 110: ...Hardware configuration CNC 8060 110 User notes REF 1709...
Page 111: ...Hardware configuration CNC 8060 111 User notes REF 1709...