![Fagor BCSD Installation Manual Download Page 32](http://html1.mh-extra.com/html/fagor/bcsd/bcsd_installation-manual_3219463032.webp)
·32·
Installation manual
BCSD
System
3.
CABLES
R
EF
. 1711
C
onne
cti
on betwee
n
SCD
sp
indl
e drive and
BCSD
axi
s
dri
v
e
3.3
Connection between SCD spindle drive and BCSD axis drive
Cable name: BSC-SA
Cable between X6 connector of SCD spindle drive and CN3 connector of BCSD axis drive.
Length: 300 mm.
Connector:
1 x 5-pin male Phoenix minicombicon connector (3.5 mm pitch) on the SCD.
1 x RJ45 on the BCSD.
Pinout:
Characteristics of the CAN cable:
Type Shielded.
Twisted pairs (1 x 2 x 0.22 mm2).
Flexibility: Superflexible.
Minimum static bending radius of 50 mm and a dynamic radius of 95 mm.
Cover: PUR.
Impedance: Cat.5 (100 W - 120 W).
1
2
3
4
5
1
2
3
4
5
Pin
Pin
6
7
8
CAN L
CAN H
SCD X6
BCSD CN3
CAN L
SHIELD
CAN H
Metallic housing