background image

 

For

 

Customer

 

Service:

 

Call

 

1

866

GO

 

FAGOR

 

 

www.fagorcommercial.com

 

|

  

P.

 

13

INSTALLATION

 

CHECKLIST

 

 
 
 

 

 

CHECK

 

OFF

 

THE

 

FOLLOWING

 

ITEMS

 

AS

 

THEY

 

ARE

 

COMPLETED

 

BEFORE

 

PROCEEDING

 

TO

 

OPERATE

 

OR

 

SERVICE

 

THE

 

DISHWASHER.

 

 

 

Has

 

the

 

dishwasher

 

been

 

properly

 

leveled?

 

 

 

Has

 

the

 

service

 

voltage

 

been

 

checked

 

to

 

ensure

 

that

 

it

 

meets

 

the

                                                                                                       

requirements

 

listed

 

on

 

the

 

dishwasher

 

specifications

 

(Page

 

2)?

 

 

 

Circuit

 

Breaker

 

size

 

______

 

Voltage

 

______

 

Phase

 

_______

 

Existing

 

or

 

New

 

electrical

 

install

 

_______

 

 

 

Has

 

the

 

dishwasher

 

been

 

properly

 

grounded?

 

 

 

Are

 

the

 

electrical

 

connections

 

and

 

plumbing

 

pipes

 

tightening

 

to

 

proper

 

torque

 

levels?

 

 

 

Has

 

been

 

installed

 

with

 

the

 

supplied

 

water

 

hose?

 

If

 

not,

 

Specify

 

specs

 

of

 

the

 

water

 

hose

 

install

 

 

Thread_____

 

Size

 

______

 

Brand

 

______

 

 

 

Flush

 

water

 

supply

 

line

 

before

 

opening

 

water

 

valve

 

 

 

Is

 

the

 

water

 

valve

 

open?

 

 

 

Is

 

the

 

incoming

 

water

 

supply

 

at

 

20

 ‐ 

25

 

psi?

 

 

 

Verify

 

water

 

hose,

 

drain

 

hose

 

and

 

chemical

 

hoses

 

are

 

not

 

kinked?

 

 

 

Is

 

the

 

hot

 

water

 

supply

 

at

 

the

 

optimum

 

temperature

 

(140ºF)?

 

If

 

not,

 

list

 

water

 

temperature

 

_______

 °F

  

 

 

Is

 

the

 

water

 

hardness

 ≤

2.0gpg/34.2ppm

 

and

 

PH

 

level

 

7

 ‐ 

8.5ph?

 

 

 

Has

 

the

 

drain

 

plumbing

 

been

 

installed

 

according

 

to

 

the

 

instructions

 

in

 

this

 

manual?

 

 

 

Height

 

of

 

the

 

drain

 

hose

 

______

  

Air

 

gap

 

size

 

_______

  

 

 

Was

 

the

 

drain

 

installed

 

to

 

a

 

garbage

 

disposal?

 

If

 

yes,

 

has

 

been

 

installed

 

a

 

back

 

flow

 

safety

 

in

 

case

 

the

 

garbage

 

disposal

 

fail?

 

____

 

Damages

 

to

 

a

 

drain

 

pump

 

due

 

to

 

a

 

failure

 

of

 

a

 

garbage

 

disposal

 

will

 

not

 

be

 

covered

 

under

 

warranty

 

 

 

Is

 

the

 

overflow

 

tube

 

with

 

the

 

O

ring

 

fitted

 

in

 

its

 

position

 

inside

 

the

 

tank

 

 

 

Is

 

the

 

detergent

 

for

 

commercial

 

dishwashers?

 

 

 

Have

 

you

 

adjusted

 

the

 

amount

 

of

 

detergent

 

/

 

rinse

 

going

 

to

 

the

 

machine?

 

____

 

Adjustments

 

on

 

detergent/rinse

 

pump

 

are

 

not

 

cover

 

under

 

warranty.

 

Please

 

refer

 

to

 

page

 

18

 

for

 

instructions.

 

 

In

 

order

 

to

 

validate

 

your

 

warranty

 

this

 

checklist

 

must

 

be

 

return

 

to

 

Fagor

 

along

 

with

 

the

 

product

 

registration

 

card.

 

 

MODEL

 

NO.__________________________

 

SERIAL

 

NO.___________________________

 

INSTALLATION

 

DATE

 

___________________

 

SERVICE

 

REP.

 

NAME

 

___________________

 

PHONE

 

 

___________________________

 

Registration

 

can

 

be

 

completed

 

by

 

mail,

 

phone,

 

and

 

fax

 

or

 

on

 

the

 

website

 

www.fagorcommercial.com

 

Fax:

 

3057790173

 

13105

 

NW

 

47

 

Ave.

 

Opa

 

Locka,

 

FL

 

33054

 

[email protected]

 

Summary of Contents for AD-48W

Page 1: ...SERVICE MANUAL 2013 UNDERCOUNTER ALL PURPOSE DISHWASHERS UNDERCOUNTER DISHWASHER Models AD 48 W AD 64 CW AD 72 W...

Page 2: ...NSTALLATION 7 REQUESTED QUALITY OF THE WATER 8 WATER DRAINAGE INSTALLATION 8 ELECTRICAL CONNECTION 9 TRANSFORMATION OF PHASES 10 INSTALLATION CHECKLIST 13 OPERATION 14 TURNING THE MACHINE ON 14 PREPAR...

Page 3: ...F Rinse time Seconds 15 Flow rinse pressure 20 25 psi Total Time Seconds 3 settings 60 90 180 Wash Pump Motor Dimensions Shipping Motor hp 1 hp Width 24 1 4 616 mm Depth 27 1 2 698 mm Temperatures Hei...

Page 4: ...27 1 2 698 mm Temperatures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 12 318mm Rinse 180 F 82 C Rack 20 x 20 500mm x 500mm Shipping weight 160 lbs 73 kg Shipping volume cu ft 15...

Page 5: ...m Depth 27 1 2 698 mm Temperatures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 16 420mm Rinse 180 F 82 C Rack 20 x 20 500mm x 500mm Shipping weight 174 lbs 79 kg Shipping volume cu...

Page 6: ...damage should be noted and reported to the delivering carrier immediately If damaged open and inspect the contents with the carrier In the event that the exterior is not damaged yet upon opening there...

Page 7: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 5 AD 72W A Water inlet D Drain hose E Electrical Cable R Terminal Block ax 10 Drain by gravity...

Page 8: ...ance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation Any transformations or changes mad...

Page 9: ...solenoid valve is opened during the cycle THE DISPLAY OF THE PRESSURE GAUGE SHALL BE CLEARLY VISIBLE OF THE OPERATOR OF THE MACHINE THE GAUGE SHALL HAVE INCREMENTS OF 1 psi 7 kpa OR SMALLER AND SHALL...

Page 10: ...the machine Adaptor supplied for female garden hose connection FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 2 GRAINS OR 10 F AND PH BEYOND THE RANGE OF 7 0 8 5 A WATER CONDITIONER MUST BE INSTALLED...

Page 11: ...east 39 in 1000 mm of electrical power cord slack from back panel of the unit to the wall to facilitate cleaning behind the dishwasher Install a circuit breaker in accordance to required consumption g...

Page 12: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 10 TRANSFORMATION OF PHASES AD 64 CW AD 72 W...

Page 13: ...P 11 T S R N Clear Cap Yellow Green Wire Bridge Blue Cap White Wire Ground Line Line Note Bridge may have a Brown wire FI 64W FI 72W 208 220 volts 1 phase 5 4 3 2 1 2 Blue Wires Brown Wire Gray Wire B...

Page 14: ...en Wire Bridge Blue Cap White Wire Ground Line Line Note Bridge may have a Brown wire FI 64W FI 72W 208 220 volts 1 phase 5 4 3 2 1 2 Blue Wires Brown Wire Gray Wire Black Wire 2 Brown Wires Black Wir...

Page 15: ...Is the water hardness 2 0gpg 34 2ppm and PH level 7 8 5ph Has the drain plumbing been installed according to the instructions in this manual Height of the drain hose ______ Air gap size _______ Was t...

Page 16: ...s are displayed before putting the machine to wash WASHING NOTE All models are fitted with Thermo stop The temperature of the incoming water should be higher than 120 F 50 C Ideal temp 140 F 60 C If i...

Page 17: ...he button P1 3 for 5 seconds Fig 9 The led number 4 will illuminate during operation Wait until the led 3 turns off 3 minutes 20 seconds Take out scrap basket for cleaning by twisting to the left Fig...

Page 18: ...t panel of the machine Locate the detergent dispenser Fig 9 and regulate according to the flow chart Fig 9a For the Rinse turn the button counterclockwise to get more rinse aide and clockwise for less...

Page 19: ...ntain dishwasher at optimum conditions it is requested to remove lime and corrosion deposits on a frequent basis A de liming solution should be available from your chemical supplier Read and follow al...

Page 20: ...e at terminal 2 brown and GND If no voltage P1 is possible stuck Faulty rinse fill valve V Verify the wiring and proper voltage at valve if correct replace fill valve Dishwasher will NOT RUN after the...

Page 21: ...ax 25 psi Clogged or obstructed rinse arms Remove and clean rinse arms nozzles Dishwasher FILLS slowly and or rinse is weak Poor water pressure Verify the inlet water pressure is at a min of 20 psi an...

Page 22: ...or damaged replace pressure switch P2 Machine temperatures or pressure may not be to specification Wait until sanitized rinsing temperature reached a min of 180 F Check out your incoming water temper...

Page 23: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 21 ELECTRICAL DIAGRAMS AD 48 W...

Page 24: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 22 AD 64 CW AD 72 W...

Page 25: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 23 WIRING SCHEMATICS n black a blue r red b white g grey m brown na orang AD 48 W...

Page 26: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 24 na orange ve green vi violet rs pink am ve yellow green am yellow n black a blue r red b white g grey m brown AD 64 CW AD 72...

Page 27: ...eating element for tank 2800W 230V Z211903 Rinsing nozzle Z211903 Rinsing nozzle Z213014 Safety thermostat Z213014 Safety thermostat Z223005 Safety pressure switch Z223005 Safety pressure switch Z7011...

Page 28: ...between 25 and 2 0 grains per gallon pH level between 7 0 8 5 and TDS level at 250 PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation...

Page 29: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 27 Fagor Commercial Inc 13105 NW 47th Ave Miami Fl 33054 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Reviews: