Page 1: ...SERVICE MANUAL 2013 UNDERCOUNTER ALL PURPOSE DISHWASHERS UNDERCOUNTER DISHWASHER Models AD 48 W AD 64 CW AD 72 W...

Page 2: ...NSTALLATION 7 REQUESTED QUALITY OF THE WATER 8 WATER DRAINAGE INSTALLATION 8 ELECTRICAL CONNECTION 9 TRANSFORMATION OF PHASES 10 INSTALLATION CHECKLIST 13 OPERATION 14 TURNING THE MACHINE ON 14 PREPAR...

Page 3: ...F Rinse time Seconds 15 Flow rinse pressure 20 25 psi Total Time Seconds 3 settings 60 90 180 Wash Pump Motor Dimensions Shipping Motor hp 1 hp Width 24 1 4 616 mm Depth 27 1 2 698 mm Temperatures Hei...

Page 4: ...27 1 2 698 mm Temperatures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 12 318mm Rinse 180 F 82 C Rack 20 x 20 500mm x 500mm Shipping weight 160 lbs 73 kg Shipping volume cu ft 15...

Page 5: ...m Depth 27 1 2 698 mm Temperatures Height 38 1 2 978 mm Wash 150 F 66 C Max clearance for dishware 16 420mm Rinse 180 F 82 C Rack 20 x 20 500mm x 500mm Shipping weight 174 lbs 79 kg Shipping volume cu...

Page 6: ...damage should be noted and reported to the delivering carrier immediately If damaged open and inspect the contents with the carrier In the event that the exterior is not damaged yet upon opening there...

Page 7: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 5 AD 72W A Water inlet D Drain hose E Electrical Cable R Terminal Block ax 10 Drain by gravity...

Page 8: ...ance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation Any transformations or changes mad...

Page 9: ...solenoid valve is opened during the cycle THE DISPLAY OF THE PRESSURE GAUGE SHALL BE CLEARLY VISIBLE OF THE OPERATOR OF THE MACHINE THE GAUGE SHALL HAVE INCREMENTS OF 1 psi 7 kpa OR SMALLER AND SHALL...

Page 10: ...the machine Adaptor supplied for female garden hose connection FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 2 GRAINS OR 10 F AND PH BEYOND THE RANGE OF 7 0 8 5 A WATER CONDITIONER MUST BE INSTALLED...

Page 11: ...east 39 in 1000 mm of electrical power cord slack from back panel of the unit to the wall to facilitate cleaning behind the dishwasher Install a circuit breaker in accordance to required consumption g...

Page 12: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 10 TRANSFORMATION OF PHASES AD 64 CW AD 72 W...

Page 13: ...P 11 T S R N Clear Cap Yellow Green Wire Bridge Blue Cap White Wire Ground Line Line Note Bridge may have a Brown wire FI 64W FI 72W 208 220 volts 1 phase 5 4 3 2 1 2 Blue Wires Brown Wire Gray Wire B...

Page 14: ...en Wire Bridge Blue Cap White Wire Ground Line Line Note Bridge may have a Brown wire FI 64W FI 72W 208 220 volts 1 phase 5 4 3 2 1 2 Blue Wires Brown Wire Gray Wire Black Wire 2 Brown Wires Black Wir...

Page 15: ...Is the water hardness 2 0gpg 34 2ppm and PH level 7 8 5ph Has the drain plumbing been installed according to the instructions in this manual Height of the drain hose ______ Air gap size _______ Was t...

Page 16: ...s are displayed before putting the machine to wash WASHING NOTE All models are fitted with Thermo stop The temperature of the incoming water should be higher than 120 F 50 C Ideal temp 140 F 60 C If i...

Page 17: ...he button P1 3 for 5 seconds Fig 9 The led number 4 will illuminate during operation Wait until the led 3 turns off 3 minutes 20 seconds Take out scrap basket for cleaning by twisting to the left Fig...

Page 18: ...t panel of the machine Locate the detergent dispenser Fig 9 and regulate according to the flow chart Fig 9a For the Rinse turn the button counterclockwise to get more rinse aide and clockwise for less...

Page 19: ...ntain dishwasher at optimum conditions it is requested to remove lime and corrosion deposits on a frequent basis A de liming solution should be available from your chemical supplier Read and follow al...

Page 20: ...e at terminal 2 brown and GND If no voltage P1 is possible stuck Faulty rinse fill valve V Verify the wiring and proper voltage at valve if correct replace fill valve Dishwasher will NOT RUN after the...

Page 21: ...ax 25 psi Clogged or obstructed rinse arms Remove and clean rinse arms nozzles Dishwasher FILLS slowly and or rinse is weak Poor water pressure Verify the inlet water pressure is at a min of 20 psi an...

Page 22: ...or damaged replace pressure switch P2 Machine temperatures or pressure may not be to specification Wait until sanitized rinsing temperature reached a min of 180 F Check out your incoming water temper...

Page 23: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 21 ELECTRICAL DIAGRAMS AD 48 W...

Page 24: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 22 AD 64 CW AD 72 W...

Page 25: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 23 WIRING SCHEMATICS n black a blue r red b white g grey m brown na orang AD 48 W...

Page 26: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 24 na orange ve green vi violet rs pink am ve yellow green am yellow n black a blue r red b white g grey m brown AD 64 CW AD 72...

Page 27: ...eating element for tank 2800W 230V Z211903 Rinsing nozzle Z211903 Rinsing nozzle Z213014 Safety thermostat Z213014 Safety thermostat Z223005 Safety pressure switch Z223005 Safety pressure switch Z7011...

Page 28: ...between 25 and 2 0 grains per gallon pH level between 7 0 8 5 and TDS level at 250 PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation...

Page 29: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 27 Fagor Commercial Inc 13105 NW 47th Ave Miami Fl 33054 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...