REQUESTED QUALITY OF THE WATER
‐
Hardness:
5
‐
10º
F
‐
Conductivity
200
‐
2000
µS
‐
pH
6.5
–
7.5
‐
Chloride’s
concentration
<
150
m
g/litre
‐
Chlorine
0.2
‐
0.5
mg/litre
‐
Impurities
<
0,08
mm
It
is
necessary
to
remove
all
foreign
debris
from
the
water
line
that
may
potentially
get
trapped
in
the
valves
or
cause
an
obstruction,
prior
to
connecting
to
the
machine.
Use
only
the
supplied
hoses
(3/4”
Female
hose
connector)
at
the
water
connections.
Failure
to
do
so
may
result
in
damage
to
the
solenoid
valve
threads
and
leaking.
Tighten
by
hand.
Connect
the
bent
side
of
the
hose
to
the
machine.
Adaptor
supplied
for
¾”
female
garden
hose
connection.
FOR
HARD
WATER
SUPPLIES
WITH
A
HARDNESS
OF
OVER
2
GRAINS
OR
10ºF
AND
PH
BEYOND
THE
RANGE
OF
7.0
–
8.5,
A
WATER
CONDITIONER
MUST
BE
INSTALLED.
Slowly
turn
on
the
water
supply
to
the
machine
after
the
incoming
fill
line
and
the
drain
line
have
been
installed.
Check
for
any
leaks
and
repair
as
required.
All
leaks
must
be
repaired
prior
to
placing
the
machine
in
operation.
WATER
DRAINAGE
INSTALLATION
Attach
the
drain
hose
as
shown
in
Fig.
5.
It
is
recommended
to
affix
a
siphon
pipe
to
prevent
odors.
All
piping
from
the
machine
to
the
drain
must
be
a
minimum
1
‐
1/2”
I.P.S.
There
should
also
be
an
air
gap
between
the
machine
drain
line
and
the
drain.
For
natural
overflow
efficiency
use
floor
drain.
Fig.
5
2
3/
8"
D
=
Drain
hose
C
=
Drain
collector
A
=
Air
Gap
F
=
Scrap
Basket