FOR OPTIMAL APPLICATION AND USE OF THE STRABUC 918 AND STRABUC 930 PLEASE READ THE INSTRUCTIONS AND CONSULT EXPLANATORY DIAGRAMS.

IMPORTANT:

 ALL INSTALLATION OPERATIONS MUST BE PERFORMED BY A QUALIFIED TECHNICIAN, IN OBSERVANCE OF THE EN 12453 - EN 12445 SAFETY REGULATIONS

AND MACHINERY DIRECTIVE 2006/42/CE.
CAREFUL RISK ANALYSIS IS REQUIRED UNDER APPLICABLE REGULATIONS.

GENERAL COMMENTS
STRABUC 918

 and 

STRABUC 930

 are a fully retractable, belowground, oil-hydraulic steel traffic control post intended to prevent unauthorised vehicular access. It is an

oil-hydraulic operator with a built-in hydraulic main unit. The Elpro S40 electronic programmer is installed externally, in a protected place. The traffic control post comes
with a series of accessories that guarantee the necessary safety and the required operations, in order to make the operator suitable for installation in all public and
private settings.
STRABUC 918: bollard with retractable post of steel, 4 mm thickness. Stainless steel option available. For both versions an optional electro/solenoid-valve is possible for
automatic lowering in case of power failure.
STRABUC 930 HEAVY ARMOURED: bollard with retractable post of steel, 12 mm thickness. On request the unit can be fitted with an electro/solenoid-valve for automatic
lowering in case of power failure, and an 

armoured lock barrel

, removable only by a custom-made key, to provide burglar-proof extra security to the post.

PRELIMINARY WARNINGS ON SAFETY AND GOOD OPERATION

Before commencing operator installation, it is essential to remember:

- That installation, checking, testing, risk analysis and subsequent maintenance work must be performed by authorised, qualified technicians.

- This operator has been designed for the use described in this manual only, and using at least the safety, control and indication accessoriesas here recommended.

- Any other application not explicitly indicated in this manual could cause malfunction, damage or personal injury.

- To check that the ground is stable, to avoid subsequent settling or deformation in the traffic control post installation area.

- To check that there are no nearby buried utility pipes.

- To check that there are no sources of electromagnetic disturbance in the immediate vicinity of and below the installation accessories such as to conceal or influence
  the magnetic/electromagnetic detection of the metal detectors and/or other electronic system control and management appliances.

- To check that the mains supply and voltage to the electric motor is 230 V at 50 Hz.

- The power supply to the operators are built-in motor must be made using electricity cables with a 1,5 mm² section for a maximum distance of 50 metres.
  For distances of over 50 metres, use electric cables with sections suited to the installation.

- Always use the original components indicated by the manufacturer to replace elements or accessories.

- Meccanica Fadini declines all responsibility for improper use not specifically indicated in this manual and any malfunction deriving from the use of materials or
  accessories other than those indicated by the manufacturer.

- The manufacturer reserves the right to make changes to this manual without giving notice.

GB

Strabuc 918 and Strabuc 930

The manufacturer, Meccanica Fadini, is not responsible for non-observance of good
installation practice and applications not indicated in this manual.

When the post is first made to rise,

remove the rubber protection band

that is fitted for 

transport reasons.

Summary of Contents for Strabuc 918

Page 1: ...I Libretto di istruzioni GB Instructions manual F Notices de montage Strabuc 918 EN 13241 EN 12453 EN 12445 made in Italy thegateopener Strabuc 930 GB Instructions Manual pages 17 32 17...

Page 2: ...work must be performed by authorised qualified technicians This operator has been designed for the use described in this manual only and using at least the safety control and indication accessoriesas...

Page 3: ...solenoid valve Optional on request Release solenoid valve Optional on request the column lowers completely in blackout conditions M8x20 TSEI inox screw Strabuc 930 heavy armoured Plastic plug to cover...

Page 4: ...il 6 Anti intrusion cabinet 7 Fit 55 recess mounted photoelectric cell receiver 8 Pre assembled magnetic loop with power supply cable 9 Post for Fit 55 photoelectric cell projector 10 Strabuc 918 or S...

Page 5: ...range a 20 cm deep layer of pebbles for rainwater drainage It is important that once the cylindrical container has been placed on the pebbles the upper portion is flush with the ground level INSTALLAT...

Page 6: ...to the 230 Volt power supply 1 Raise the post about 20 cm 2 and switch off the power supply 3 Pic 7 N B We recommend to fit a 20 F capacitor in parallel to the two phase live wires to give the traffic...

Page 7: ...cylinder holes with those in the cylindrical container cemented into the ground Pull the electric cables to the Elpro S40 programmer without tugging For distances greater than 10 metres make extensio...

Page 8: ...ehicles It prevents the traffic post from rising when vehicles pass over the coils A hole must be prepared see relative instruction sheet Specifications should always be observed for correct magnetic...

Page 9: ...een designed for the installation of possible control accessories such as intercom systems or key switches in the immediate vicinity of the traffic post pic 12 ARRANGEMENT OF VISUAL 344 Visual 344 275...

Page 10: ...wered 230 V to terminals 60 61 on the plug in card ELECTRICAL CONNECTIONS TO THE ELPRO S40 CONTROL BOARD Red Yellow Green Common Power supply 230 V 50 Hz 1 A fuse CONNECTOR FOR 3 LIGHT TRAFFIC LIGHTS...

Page 11: ...should move up on the first commanding pulse should it fail disconnect power supply and swap the connections to the live terminals Strabuc n 1 common Strabuc n 1 Strabuc 918 or Strabuc 930 with soleno...

Page 12: ...mand impulse RELEASE OPERATIONS FOR MANUAL LOWERING OF THE STRABUC 930 HEAVY ARMOURED Strabuc 930 Heavy Armoured posts can be lowered manually by following the operations shown in picture 22 Insert an...

Page 13: ...support it Unscrew the Cap protecting the Armoured lock barrel using the triangular profile key Remove the three Eyebolts the post Cover the Rubber edge and the Drilled flange Unscrew the three long...

Page 14: ...rash resistance 280 000 J 45 000 J 410 000 J Strabuc 918 Static load resistance The static load acting on the Strabuc 918 when completely lowered is considered as the weight a 20 000 kg lorry exerts w...

Page 15: ...RABUC 918 GB Date 10 01 14 The Responsible Manager Responsible Manager made in Italy the gate opener DECLARATION OF CONFORMITY of the Manufacturer Manufacturing company Model Strabuc 930 and Strabuc 9...

Page 16: ...utput 0 25 kW 0 33 HP Power consumption 330 W Power supply voltage 230 V Frequency 50 Hz Absorbed current 1 8 3 5 A 6 A max Motor rotation speed 2 800 rpm Intermittent service S3 CYLINDRICAL CONTAINER...