background image

- 29 -

GB

Strabuc 918 and Strabuc 930

REMOVING ONLY THE POST OF STRABUC 930 HEAVY ARMOURED

It is possible to remove Strabuc 930 Heavy Armoured from its seat by following steps 1) and 2) as described in pic. 23.
But in order to remove only the retractable post, carry on with the steps as subsequently described in pic. 23.

1)

2)

3)

Strabuc 930

Heavy Armoured

Strabuc 930

Heavy Armoured

Strabuc 930

Heavy Armoured

Strabuc 930

Heavy Armoured

Strabuc 930

Heavy Armoured

PIC. 23

4)

5)

6)

7)

M10

M10

To remove only the retractable post: with the Strabuc 930 Heavy Armoured version
raised using the winch, unscrew the 

three clamping nuts

 and respective washers,

positioned below the Cylindrical container.

ATTENTION: during this operation the cylindrical housing will drop: it is
therefore recommended to support it.

Unscrew the 

Cap

 protecting the 

Armoured lock barrel

 using the

triangular profile key

Remove the three 

Eyebolts

, the post 

Cover

, the 

Rubber edge

and the 

Drilled flange

Unscrew the three 

long hexagonal nuts

with their respective 

Clamping screws

 and

remove the 

Retractable post

 to leave the

Piston - hydraulic main unit

 set exposed

Remove the whole 

Reinforced Lock Barrel

 by inserting the

personalised key and turn anticlockwise

Clamping nuts
and washers

IMPORTANT: do NOT loosen or tighten the three

axial alignment dowels of the internal group.

- VIEW FROM BELOW -

CYLINDRICAL HOUSING

Protection cap

Eyebolts

Post cover

Rubber edge

Drilled flange for
edge tightening

Manual release
cover security
flap

Armoured lock barrel

Personalised key for

armoured lock barrel

Triangular
profile key

ATTENTION: during the assembly phase it is important to
reposition the internal unit in exactly the same position as
before without screwing or loosening the three axial
alignment dowels.

Summary of Contents for Strabuc 918

Page 1: ...I Libretto di istruzioni GB Instructions manual F Notices de montage Strabuc 918 EN 13241 EN 12453 EN 12445 made in Italy thegateopener Strabuc 930 GB Instructions Manual pages 17 32 17...

Page 2: ...work must be performed by authorised qualified technicians This operator has been designed for the use described in this manual only and using at least the safety control and indication accessoriesas...

Page 3: ...solenoid valve Optional on request Release solenoid valve Optional on request the column lowers completely in blackout conditions M8x20 TSEI inox screw Strabuc 930 heavy armoured Plastic plug to cover...

Page 4: ...il 6 Anti intrusion cabinet 7 Fit 55 recess mounted photoelectric cell receiver 8 Pre assembled magnetic loop with power supply cable 9 Post for Fit 55 photoelectric cell projector 10 Strabuc 918 or S...

Page 5: ...range a 20 cm deep layer of pebbles for rainwater drainage It is important that once the cylindrical container has been placed on the pebbles the upper portion is flush with the ground level INSTALLAT...

Page 6: ...to the 230 Volt power supply 1 Raise the post about 20 cm 2 and switch off the power supply 3 Pic 7 N B We recommend to fit a 20 F capacitor in parallel to the two phase live wires to give the traffic...

Page 7: ...cylinder holes with those in the cylindrical container cemented into the ground Pull the electric cables to the Elpro S40 programmer without tugging For distances greater than 10 metres make extensio...

Page 8: ...ehicles It prevents the traffic post from rising when vehicles pass over the coils A hole must be prepared see relative instruction sheet Specifications should always be observed for correct magnetic...

Page 9: ...een designed for the installation of possible control accessories such as intercom systems or key switches in the immediate vicinity of the traffic post pic 12 ARRANGEMENT OF VISUAL 344 Visual 344 275...

Page 10: ...wered 230 V to terminals 60 61 on the plug in card ELECTRICAL CONNECTIONS TO THE ELPRO S40 CONTROL BOARD Red Yellow Green Common Power supply 230 V 50 Hz 1 A fuse CONNECTOR FOR 3 LIGHT TRAFFIC LIGHTS...

Page 11: ...should move up on the first commanding pulse should it fail disconnect power supply and swap the connections to the live terminals Strabuc n 1 common Strabuc n 1 Strabuc 918 or Strabuc 930 with soleno...

Page 12: ...mand impulse RELEASE OPERATIONS FOR MANUAL LOWERING OF THE STRABUC 930 HEAVY ARMOURED Strabuc 930 Heavy Armoured posts can be lowered manually by following the operations shown in picture 22 Insert an...

Page 13: ...support it Unscrew the Cap protecting the Armoured lock barrel using the triangular profile key Remove the three Eyebolts the post Cover the Rubber edge and the Drilled flange Unscrew the three long...

Page 14: ...rash resistance 280 000 J 45 000 J 410 000 J Strabuc 918 Static load resistance The static load acting on the Strabuc 918 when completely lowered is considered as the weight a 20 000 kg lorry exerts w...

Page 15: ...RABUC 918 GB Date 10 01 14 The Responsible Manager Responsible Manager made in Italy the gate opener DECLARATION OF CONFORMITY of the Manufacturer Manufacturing company Model Strabuc 930 and Strabuc 9...

Page 16: ...utput 0 25 kW 0 33 HP Power consumption 330 W Power supply voltage 230 V Frequency 50 Hz Absorbed current 1 8 3 5 A 6 A max Motor rotation speed 2 800 rpm Intermittent service S3 CYLINDRICAL CONTAINER...