background image

3

INSTRUCTIONS TO FIT THE VERTICAL AND HORIZONTAL MEC 200 OPERATORS TO A SLIDING GATE

FOR A PROPER AND PERFECT PERFORMANCE OF MEC 200 READ THE INSTRUCTIONS THAT ARE OUTLINED IN THIS MANUAL AND 

KEEP TO THE DIAGRAMS.

Mec 200 is an extremely versatile system and can suit any sliding gate as it can be mounted either vertically or horizontally, and the 

motor is available in different power specifications such as 0,37 kW (0,5 HP single- and three-phase); 0,73 kW (1,0 HP single- and 

three-phase); 1,1 kW (1,5 HP three-phase only). It is a strong and reliable automation. It has a torque control device that can be 

manually adjusted; worm and gear are made of bronze and steel and are supported by bearings, in an oil bath. A manual overriding 

system allows manual operations of the gate in emergency events like power failure.
POINTS TO CHECK WITH THE GATE

Check that the gate track is well fixed to a solid foundation to prevent deformation which would result into an unbalanced travelling 

of the gate.

 IMPORTANT:

 

• make sure that gate stops are fixed in the open and closed gate positions so that the gate does not over travel the

 

   permitted limit and go out of the upper guide;

 

• make sure that a system be mounted to the gate to prevent it from falling over

;

 

• make sure that, once at the end of the permitted travel, the gate does not hit the gate posts or special gate

 

   stops to avoid damages to its structure.

FITTING MEC 200 ON TO THE FIXING BASE PLATE

The first operation is to fix the fixing base plate to the ground and make sure that it is perfectly levelled. Fixing distances are as 

indicated in pic. 1 here below. Fixing is by setting the plate into a concrete foundation.

Remove the Mec 200 cover by loosening the three screws and pulling it upwards; temporary fix the Mec 200 operator to the fixing 

base plate by means of the four screws (pic. 2).

English

MEC 200

Pic. 2

Pic. 1

80

GROUND

GROUND

PROTECTION

COVER

PROTECTION

COVER

SCREWS TO FIX

THE COVER

MEC 200 HORIZONTAL

MEC 200 HORIZONTAL

MEC 200 VERTICAL

FIXING BASE PLATE

TO SET IN CONCRETE

SPIRIT LEVEL

120

90

80

GROUND

MEC 200 VERTICAL

FIXING BASE PLATE

TO SET IN CONCRETE

SCREWS TO FIX

THE COVER

No. 4

FIXING SCREWS

No. 4

FIXING SCREWS

80

80

120

90

!

electro-mechanical sliding gate operator

Summary of Contents for MEC 200

Page 1: ... 12445 Electro mechanical sliding gate operator Vertical and horizontal installation Gear movements and worm gear coupling in oil bath fully mounted on ball bearings MEC 200 GB Instructions manual pages 1 8 the gate opener ...

Page 2: ...on The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and components of the installation risk analysis verification of safety accessories verification of impact forces and reporting of residual risks INFORMATION FOR END USERS The end user is required to read carefully and to receive information concerning onl...

Page 3: ... gate stops are fixed in the open and closed gate positions so that the gate does not over travel the permitted limit and go out of the upper guide make sure that a system be mounted to the gate to prevent it from falling over make sure that once at the end of the permitted travel the gate does not hit the gate posts or special gate stops to avoid damages to its structure FITTING MEC 200 ON TO THE...

Page 4: ...out friction pic 4 IMPORTANT before definitely fixing any component make sure that the rack can mesh the driving gear of Mec 200 so that the whole system gate included can be smoothly run by hand the full travel open and close without any friction Remove the 2 mm shims only after having fixed the rack An adequete clearance between rack and gear has thus been achieved pic 4 English Pic 3 Pic 4 MEC ...

Page 5: ...s the installer s responsibility to lay the connection pipes and tubes as properly and correctly required IMPORTANT all the electrical equipment to be properly earthed English MEC 200 Pic 5 Pic 6 15 mm LIMIT SWITCH STRIKING PLATE TO BE FIXED TO THE GATE BY BOLTS LIMIT SWITCH ROLLER FADINI 1 2 9 8 3 11 4 5 17 6 7 10 12 13 13 14 15 16 230 V n 2x1 n 2x1 n 4x1 n 4x1 cable RG58 n 4x1 5 n 4x1 5 n 4x1 n ...

Page 6: ...be adjusted to the gate weight Adjusting is by a screw which is located on one side of the operator A special spanner E17 is provided with the equipment for this purpose unscrew the locknut the more you tighten the screw clockwise the more you increase the operator torque by unscrewing it torque is decreased Once set it to meet the site requirements tighten the locknut hard pic 9 ELECTRIC MOTOR CO...

Page 7: ...el Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to authorized inspectors officers an...

Page 8: ...e phase 40 Nm 1 200 kg 19 5 kg 19 kg Three phase 40 Nm 1 250 kg 18 5 kg 18 kg Single phase 80 Nm 1 32 10 m 1 25 C 80 C Oil Fadini Item 706L 1 800 kg 23 5 kg 23 kg IP 55 inside the cover mechanical Three phase 80 Nm 1 850 kg 21 5 kg 21 kg Three phase 110 Nm 2 000 kg 25 5 kg 25 kg Mec 200 vertical Mec 200 horizontal OVERALL DIMENSIONS FITTING ACCESSORIES FOR INSTALLING Zinc coated steel base plate 2...