PIC. 13
• Please note that a
low voltage
cut off switch is fitted to the
right side of the control box. The contacts are closed when the
operator lid is put back (Pic. 13).
• Instead of the low voltage cut off microswitch (ie. LOGIC switch)
see Pic. 13, you can request and have a line switch fitted to
interrupt the mains. Like the other one, it is also controlled by
the operator lid when you remove it or put it back to the original
correct position by means of the specially toothed key.
Once the lid is locked back, you have the certainty of the made
contact.
9
PIC. 12
ELPRO 15 PLUS
1
2
3
4
5
6
7
8
9
10
11
12
13
1 4
1 5
1 6
1 71
819
2 0
ELPRO15plus 1.4
FADINI
COD
.E01
5PL
US
PRO
D:0
4/02
/05
PN:1
0 VA
PRI: 2
X11
5 V
SEC
: 12
V - 5
VA
4
00 m
AT
SEC
: 12
V - 5
VA
4
00 m
AT
M
K
A
20
-4
50
µ
F
2
0
+-
5%
U
n
40
0
V
ac
B
U
n
45
0
V
ac
C
25
/8
5/
21
P
O
50
Hz
EARTH
LOGIC SWITCH
ELPRO 15 PLUS
ELECTRONIC PROGRAMMER
Flashing lamp:
4
7
Power supply:
Capacitor and Single-phase Motor:
ELECTRICAL POWER CONNECTIONS
-
+
T1
MOTOR RUN TIME
OPEN/CLOSE
from 2 up to 255s
T2
-
+
DWELL TIME
from 2 up to 255s
230V
±
10% MOTOR
23
24
EXT Capacitor
20
µ
F
(fitted)
COMMON
M
16
14
15
17
18
19
20
POWER SUPPLY
230V
±
10% 50Hz
SINGLE-PHASE
Courtesy Light
230V max 100W:
22 21
Trimmer T3
from 2s up to 255s
-
+
Hold on switched (Deadman) control:
Automatic / Semiautomatic:
OPERATING MODES
Open and Close operations are achieved "by holding a switch on"
(no relay self-holding in involved) therefore a phisical attendance
is required to keep the gate opening or closing until either the
button or key is released.
Automatic Operation: any pulse opens the gate, the gate stays open as
long as the Dwell time expires as set by T2 trimmer, then it closes
automatically, no pulsing is required.
Semi-automatic Operation: any pulse opens the gate that stays open. A
second pulse to Close is required for the gate to close.
ON: Pre-flashing
OFF: No pre-flashing
ON: Lamp is not operating during
Dwell time. Automatic mode.
OFF: It flashes during Dwell Time.
Automatic Mode.
DIP-SWITCH 4 and 7:
3
DIP-SWITCH N
°
3
ON= Automatic Closing
OFF= No Automatic. Semi-
automatic closing by pulse
6
DIP-SWITCH N
°
6=ON
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
T5
-
+
MOTOR
TORQUE
from 40% up to 100%
Pedestrian Opening:
Trimmer T4
-
+
from 3 to 30s. It can be activated
by any pulse (eg. by remote control)
superior to 2s
4
3
COMMON
COMMON
OPEN
NO
How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even by remote control) is
not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time the gate is closed automatically.
T4 trimmer on to zero, Dip-Switch 3=ON.
Time clock
installation:
DIP-SWITCH No.3=ON Automatic Closing
3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
-
+
Pedestrian Trimmer T4
set on to zero
COMMON
OPEN
4
3
External Time Clock
PLUS
15
Drwg. No.
4136