background image

The electronic control panel Elpro 15 Plus, new generation, is designed to operate the sliding gate operator Girri 130. Power supply is 230V 50Hz single-phase. Built in full
compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations.
Fitting operations are recommended by a qualified technician in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.

PLEASE NOTE:
- The control panel is fitted inside Girri 130.
- Make sure that the power supply to the electronic programmer is 230V 

±

10%

-  Make sure that the power supply to the Electric Motor is 230V 

±

10%

- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm

2

 section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50m.

Use 1mm

2

 section wires for limit switches, photocells, push-buttons/key-switch and accessories.

-  Bridge terminals 1 and 2 if no photocells are required.
-  Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.

DIP-SWITCH

1

4 5 6 7 8

2

ON

OFF

3

Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function

In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230V 

±

10%

- Make sure that the power supply to the Electric Motor is 230V 

±

10%

- Check fuses
- Check photocells if contacts are normally closed
- Check that no voltage drop has occurred from the control panel to the electric motor

Led Status Indication:

L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate moving
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open

1

12

2

13

COMMON

RADIO

CONT

ACT

7

3

26 27 28 3

NEUTRAL

Push Button Switch Pulin 3:

Photocells and Safety
Edge:

PHOTOCELLS

AND SAFETY

EDGE

24V (500 mA) OUTPUT

 (MAX. LOAD:

2 PAIRS PHOTOCELLS

1 RADIO RECEIVER)

Light ON = Open gate
Light OFF = Close gate
Flashing (fast) 0.5s= Closing gate
Flashing (normally) 1s= Opening gate
Flashing (slowly) 2s= gate is stopped

24V 3W Indication Light:

3

11

Led to indicate
status of Open -
Stop - Close
switches

LOW VOLTAGE ELECTRICAL CONNECTIONS

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it on closing once obstacle
       is removed

OFF: Photocells do not stop gate while
        opening, reverse it in case of an
        obstacle on closing

Button switch:

3

4

5

6

STOP

COMMON

OPOEN

CLOSE

Radio Contact:

- Open/Close (Standard)
- Travel reversing on
  pulsing
- Step by step

2

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

ON: Step by step. Stop in between

OFF: Standard operating mode

DIP-SWITCH 2 and 5 (NEVER set BOTH of them
ON at the same time):

Limit switch:

LIMIT SWITCH

CLOSE

COMMON

10

8

9

LIMIT SWITCH

OPEN

8

PIC. 12

PLUS

15

Drwg. No.

4136

INDICATION LAMP 24V max 3W

M

F4 Fuse=630mA
24V Protection

PULIN 3

26 27 28 3

DIP-SWITCH

ON

OFF

1

4 5 6 7 8

2 3

F1 Fuse=5A

230V Mains

RADIO PLUG-IN

CARD

CONNECTOR

MOTOR RUN
TIME
OPEN/CLOSE
from 2 up to
255s

DWELL
TIME from 2
up to 255s

PEDESTRIAN
OPENING
from 3 up
to 30s

T3

T1

ELPRO 15 PLUS

24V OUTPUT (max. load:

2 PAIRS PHOTOCELLS

1 RADIO RECEIVER)

1

7

4

10

11

12

13

2

8

5

3

9

6

STOP

COMMON

OPEN

CLOSE

PHOTOCELLS

RADIO CONTACT

LIMIT SWITCH CLOSE

LIMIT SWITCH OPEN

LIMIT SWITCH COMMON

L1

L2

L3

L4

L5

L6

L7

L8

L9

T2

21

22

23

24

EXT CAP

ACITOR

20

µ

F

COUR

TESY LIGHT

230V max 100W

230V 25W max

FLASHING LAMP

14

16

230V 50Hz

SINGLE-PHASE

VOL

TAGE SUPPL

Y

15

17

18

230V 

±

10% 50Hz

SINGLE-PHASE

ELECTRIC

MOTOR

19

20

F2 Fuse=5A
230V Mains

TRANSFORMER

F3 Fuse=315mA

Transformer

Protection

T4

MOTOR
TORQUE from
40% to 100%

COURTESY
LIGHT from 2
up to 255s

T5

-

+

-

+

-

+

-

+

-

+

ELPRO 15 Plus 1.4

MICROPROCESSOR

COMMON

Summary of Contents for Girri 130

Page 1: ...G B INSTALLATION MANUAL...

Page 2: ...XING LONG SCREWS BACK COVER OPTIONAL FAN COVER OPTIONAL COOLING FAN ELECTRIC MOTOR CUT OFF LIMIT SWITCH ASSEMBLY LIMIT SWITCH STOP STRIKING PLATES LIMIT SWITCH ROD DRIVING SHAFT DRIVING COG COG PROTEC...

Page 3: ...de of the motor base plate and centring fixing plate See picture 1 showing the various components INSTRUCTIONS FOR THE INSTALLATION OF GIRRI 130 ON TO SLIDING GATES To achieve a perfect application an...

Page 4: ...MOVE IT FROM THE LONG BOLTS ADJUSTMENT NUT TO SET THE OPERATOR AT A SUITABLE HEIGHT SO THAT THE COG CAN PROPERLY MESH THE TOOTHED RACK INLET FOR THE CABLES FROM THE PUSH BUTTONS KEYSWITCHES PHOTOCELLS...

Page 5: ...he left hand side They mark the limit of the permitted travel and bring the gate to a steady halt both in the open and close positions The pIates are to be fixed by means of suitably designed brackets...

Page 6: ...switch PULIN 3 9 Close gate stop 10 Photocell transmitter TRIFO 11 cable RG58 IMPORTANT All the electrical equipment to be properly earthed FIT THE MOVING GATE WITH A METALLIC NET SHOULD THE PATTERN...

Page 7: ...E sticker on it is received PIC 11 EUROPEAN MARK CERTIFYING CONFORMITY TO THE ESSENTIAL REQUIREMENTS OF THE STANDARDS 98 37 EC IDENTIFICATION PLATE COMPONENT PARTS OF THE ELECTRONIC P C BOARD ELPRO 15...

Page 8: ...Open pulse is given L4 Close Alight whenever a Close pulse is given L5 Stop It goes off on pulsing Stop L6 Radio It goes on by pressing a transmitter button L7 Gate Status it flashes on gate moving L8...

Page 9: ...elay self holding in involved therefore a phisical attendance is required to keep the gate opening or closing until either the button or key is released Automatic Operation any pulse opens the gate th...

Page 10: ...5 0 H z MKA 20 4 5 0 F 12 5 5 Un 400 V a c B Un 450 V a c C 25 85 21 P O 5 0 H z ELPRO 15 PLUS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ELPRO15plus 1 4 MKA 20 4 5 0 F 20 5 Un 400 V a c B Un...

Page 11: ...ding to the rotation direction of the electric motor in fact during the dwell time the gate fully open automatic mode the limit switch open controls the seconds the gate has to stay open before it is...

Page 12: ...reserve the right to change the products without any previous notice Distributor s box Made in Italy CHECKING AND MAINTENANCE To achieve an optimum performance and longer life of the equipment and in...

Reviews: