The electronic control panel Elpro 15 Plus, new generation, is designed to operate the sliding gate operator Girri 130. Power supply is 230V 50Hz single-phase. Built in full
compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations.
Fitting operations are recommended by a qualified technician in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.
PLEASE NOTE:
- The control panel is fitted inside Girri 130.
- Make sure that the power supply to the electronic programmer is 230V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50m.
Use 1mm
2
section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
DIP-SWITCH
1
4 5 6 7 8
2
ON
OFF
3
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230V
±
10%
- Make sure that the power supply to the Electric Motor is 230V
±
10%
- Check fuses
- Check photocells if contacts are normally closed
- Check that no voltage drop has occurred from the control panel to the electric motor
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate moving
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
1
12
2
13
COMMON
RADIO
CONT
ACT
7
3
26 27 28 3
NEUTRAL
Push Button Switch Pulin 3:
Photocells and Safety
Edge:
PHOTOCELLS
AND SAFETY
EDGE
24V (500 mA) OUTPUT
(MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
Light ON = Open gate
Light OFF = Close gate
Flashing (fast) 0.5s= Closing gate
Flashing (normally) 1s= Opening gate
Flashing (slowly) 2s= gate is stopped
24V 3W Indication Light:
3
11
Led to indicate
status of Open -
Stop - Close
switches
LOW VOLTAGE ELECTRICAL CONNECTIONS
1
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle
is removed
OFF: Photocells do not stop gate while
opening, reverse it in case of an
obstacle on closing
Button switch:
3
4
5
6
STOP
COMMON
OPOEN
CLOSE
Radio Contact:
- Open/Close (Standard)
- Travel reversing on
pulsing
- Step by step
2
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
ON: Step by step. Stop in between
OFF: Standard operating mode
DIP-SWITCH 2 and 5 (NEVER set BOTH of them
ON at the same time):
Limit switch:
LIMIT SWITCH
CLOSE
COMMON
10
8
9
LIMIT SWITCH
OPEN
8
PIC. 12
PLUS
15
Drwg. No.
4136
INDICATION LAMP 24V max 3W
M
F4 Fuse=630mA
24V Protection
PULIN 3
26 27 28 3
DIP-SWITCH
ON
OFF
1
4 5 6 7 8
2 3
F1 Fuse=5A
230V Mains
RADIO PLUG-IN
CARD
CONNECTOR
MOTOR RUN
TIME
OPEN/CLOSE
from 2 up to
255s
DWELL
TIME from 2
up to 255s
PEDESTRIAN
OPENING
from 3 up
to 30s
T3
T1
ELPRO 15 PLUS
24V OUTPUT (max. load:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
1
7
4
10
11
12
13
2
8
5
3
9
6
STOP
COMMON
OPEN
CLOSE
PHOTOCELLS
RADIO CONTACT
LIMIT SWITCH CLOSE
LIMIT SWITCH OPEN
LIMIT SWITCH COMMON
L1
L2
L3
L4
L5
L6
L7
L8
L9
T2
21
22
23
24
EXT CAP
ACITOR
20
µ
F
COUR
TESY LIGHT
230V max 100W
230V 25W max
FLASHING LAMP
14
16
230V 50Hz
SINGLE-PHASE
VOL
TAGE SUPPL
Y
15
17
18
230V
±
10% 50Hz
SINGLE-PHASE
ELECTRIC
MOTOR
19
20
F2 Fuse=5A
230V Mains
TRANSFORMER
F3 Fuse=315mA
Transformer
Protection
T4
MOTOR
TORQUE from
40% to 100%
COURTESY
LIGHT from 2
up to 255s
T5
-
+
-
+
-
+
-
+
-
+
ELPRO 15 Plus 1.4
MICROPROCESSOR
COMMON
Summary of Contents for Girri 130
Page 1: ...G B INSTALLATION MANUAL...