5. TYPE OF SYSTEM
Pic. 4
Install the suitable corrugated pipes according to the indicated scheme, taking into account the type of terrain.
LEGEND
1. Electronic control programmer (230 Vac 3G x 1.5 mm² power cable) with plug-in radio receiver
2. Flashing light and antenna (2G x 0.5 mm² cable and RG 58 50 Ω coaxial cable)
3. Photocell (4G x 0.5 mm² receiver cable | 2G x 0.5 mm² transmi er cable)
4. Actuator with founda on box (230 Vac 4G x 1.5 mm² power cable | 3G x 0.5 mm² encoder)
5. Stop bollard
6. Transmi er photocell (2x0.5 mm²)
7. Column prepared for internal photocell
8. Electric lock (2G x 1 mm² cable)
9. Ground stop bollard
10. Key switch
11. Transmi er
12. Inspectable underground box
ATENTION
The cable specifica ons refer to a maximum length of 15 m. For longer measurements, the cable sec on must be determined
considering the power consump on of the connected devices and following the guidelines of the CEI EN 60204-1 standard.
The system must be powered at 230 V and 50 Hz,
passing
through
a
0.03
A
differen al
magnetothermal line switch (for cables over 100
m in length with a cross sec on of 2.5 mm²).
The en re system must be connected to the
ground.
!
1
2
3
3
4
4
5
5
7
7
8
9
10
11
12
12
6
6
FA
D
IN
I
GB
- 23
FOX 724 | FOX 730
Summary of Contents for FOX 724
Page 8: ...Fig 11 max 105 180 180 GRASSO GRASSO IT 8 FOX 724 FOX 730...
Page 10: ...IT 10 M8 6 5 M8 Fig 16 Fig 15 Fig 17 GRASSO 90 FOX 724 FOX 730...
Page 14: ...Fig 24 Fig 25 E19 sinistra destra sinistra destra E19 30mm 90 50mm IT 14 FOX 724 FOX 730...
Page 26: ...GB 26 FOX 724 FOX 730 Pic 11 max 105 180 180 GREASE GREASE...
Page 28: ...GB 28 M8 6 5 M8 Pic 16 Pic 15 Pic 17 GREASE 90 FOX 724 FOX 730...
Page 32: ...Pic 24 Pic 25 E19 Le Right Le Right E19 30mm 90 50mm GB 32 FOX 724 FOX 730...
Page 44: ...Fig 11 max 105 180 180 GRAISSE GRAISSE FR 44 FOX 724 FOX 730...
Page 46: ...FR 46 M8 6 5 M8 Fig 16 Fig 15 Fig 17 GRAISSE 90 FOX 724 FOX 730...
Page 50: ...Fig 24 Fig 25 E19 E19 30mm 90 50mm FR 50 Gauche Droite Gauche Droite FOX 724 FOX 730...