background image

GENERAL DESCRIPTION OF THE PRODUCT

Aproli 280 Batt is an oil-hydraulic operator for external application, fitted with an articulated arm, it is studied to open and close 
swinging gates mounted on pillars of significant dimensions. Aproli 280 Batt is designed in a single version as it can be indifferently 
mounted on the right or left side of the gate (view from inside ).
it is an oil-hydraulic product and has all the advantages that such systems can offer, such as reliability, smooth movements, adjustable 
thrust power being controlled by low and high pressure valves, and flexibility as it can suit most types of swinging gates.
Quick and easy to install. The pressure cast aluminium back bracket is fastened to the gate pillar by means of expanding bolts and 
provides support to the drive assembly, made of galvanized steel and aluminium and fixed by screws.
The pivoting shaft is made of hardened steel to ensure long lasting reliability over the time.
The driving arm is made of pressure cast aluminium and has the advantage that its last section can be adjusted to three different 
steps to meet any installation requirements, even with pillars of large dimensions. 
The operator comes in two options, fitted with a hydraulic locking valve or non locking ie. reversible (in this case an electric lock is 
to be fitted to the gate).
it is also possible to have Aproli 280 Batt in the special option with flow regulator. This is an incorporated device that can control 
the speed of the gate (in opening and closing movements independently) all along the gate travel, recommended for those heavy 
gates whose inertia is significant.
For Aproli 280 Batt to work as an automatic system it is required that an electronic control box type Elpro be fitted externally in a 
sheltered place. Operations can be selected to be either fully automatic or semiautomatic (closing by pulse), depending on the 
user’s requirements.
The system is designed to work together with accessories that ensure proper operations in full safety and reliability, making it 
suitable for any public or private applications.
A polycarbonate cover protects the inner drive unit, and a flap allows only authorized access to the control valves by means of a 
coded key for the following operations: high and low pressure adjustment, manual release and removal of the cover.

E

n

g

li

sh

3

  1 - Back bracket for gate post fixing
  2 - Motor pump-jack assembly
  3 - Cover with lockable flap for manual realasing by coded key
  4 - Complete arm assembly: it can be used for both right and left applications
  5 - Incorporated stop assembly for Aproli 280 Batt installed on the left 
  6 - Incorporated stop assembly for Aproli 280 Batt installed on the right
  7 - Arm bracket for gate fixing

COMPONENTS

Pic. 1

External oil-hydraulic operator with articulated arm 

for swinging gates mounted on large pillars

APROLI 280 Batt

2

3

4

4

6

1

7

5

Summary of Contents for APROLI 280 BATT

Page 1: ...EN 13241 EN 12453 EN 12445 APROLI 280 Batt External oil hydraulic operator with articulated arm for swinging gates mounted on large pillars 1 12 GB Instructions manual pages the gate opener ...

Page 2: ...ing on the gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including layout and components of the installation risk analysis verification of safety accessories verification of impact forces and reporting of residual risks INFORMATION FOR END USERS The end user is...

Page 3: ... it is also possible to have Aproli 280 Batt in the special option with flow regulator This is an incorporated device that can control the speed of the gate in opening and closing movements independently all along the gate travel recommended for those heavy gates whose inertia is significant For Aproli 280 Batt to work as an automatic system it is required that an electronic control box type Elpro...

Page 4: ...op in open position 9 Fit 55 photocell receiver on post mount 10 Gate electric lock 11 Gate stop in closed position 12 Fit 55 photocell transmitter on post mount 13 Chis 37 keyswitch 14 Vix 53 radio transmitter 230 V 50 Hz 10 4x1 5 mm Pic 2 General layout it is the installer s care and responsibility to properly lay the tubes required for the electrical connections English 2 3 4 1 7 8 9 11 10 4 12...

Page 5: ...n the back side towards the gate post and two underneath in this way it can meet any application requirements Pic 4 Pic 3 Pic 4 View from inside Aproli 280 Batt mounted on the right Gate post fixing bracket Arm bracket for on the gate fixing English 5 A Aproli 280 Batt as default version comes factory pre set to be installed on the left gate in closed position For Aproli 280 Batt to be installed o...

Page 6: ...ke in the most critical position when the gate is fully open Pic 5 FIXING DISTANCES Power C 460 520 580 IMPORTANT The longer is distance L from the gate hinge center the greater is the lever action the arm can exert onto the gate This specially applies to heavy gates But it is also to consider that D ie the space taken by the arm when the gate is fully open increases consequently Both factors are ...

Page 7: ...ep with both operators the motor shafts are to be rotated a few degrees in the open direction allowing for the arms to be fixed FIXING THE BACK BRACKET TO THE GATE POST The back bracket is to be fixed to the gate post by means of suitable expanding bolts using 4 of the 8 holes provided in it M8 expanding bolts to suit gate post material or brickwork Pic 8 250 150 212 120 355 400 Gate view from ins...

Page 8: ...ening direction of the gate Fit the arm and fix the retaining pin into the hole Pic 10 Pic 11 IMPORTANT the hole in the flattened surface of the square shaft is a reference point Aproli 280 Batt is factory pre set to be installed on the left If installed on the right the shaft is to be rotated 205 to get it in the correct position IMPORTANT screw M8 pin into the shaft hole to fix the arm 230 V 50 ...

Page 9: ...re a gate stop in open position cannot be fixed on the ground Aproli 280 Batt comes with an accessory open gatestop adjustable to be mounted on to the operator under the gate post fixing back bracket for the operator arm to stop against it Once satisfied it is adjusted to the required distance tighten M14 locknut and fit the cover and fasten it by M8 nut Pic 12 In closed gate position tough a gate...

Page 10: ...that the electric lock be released by the coded key and the gate pushed open by hand With the locking version releasing is by opening the flap in the front cover by the coded key and lowering the inner lever Locking again is by rising the lever and tightening it hard overtightening though is to be avoided Pic 16 ORDINARY MAINTENANCE Tighten hard External oil hydraulic operator with articulated arm...

Page 11: ...llard Road barrier Operator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by using Fadini original spare parts This document for the data included in it must be made available to ...

Page 12: ...tem 708L Shaft rotation angle 205 Weight with arm 11 kg Protection standard IP 67 40 C with specific optional accessories Ref General Catalogue ELECTRIC MOTOR Power output 0 18 kW 0 25 CV Supply voltage 230 Vac Frequency 50 Hz Absorbed power 250 W Absorbed current 1 2 A Motor rotation speed 1 350 rpm Capacitor 12 5 µF Intermittent service S3 APPLICATIONS Max gate weight per leaf 400 kg Max gate wi...