background image

Summary of Contents for CMS-50D Plus

Page 1: ......

Page 2: ...the Pulse Oximeter s features and requirements main structure functions specifications correct methods for transportation installation usage operation repair maintenance and storage etc as well as th...

Page 3: ...evice ceaselessly especially for the microcirculation barrier patients It is recommended that the sensor should not be applied to the same finger for over 2 hours For the special patients there should...

Page 4: ...s Check the main unit and all accessories periodically to make sure that there is no visible damage that may affect patient s safety and monitoring performance about cables and transducers It is recom...

Page 5: ...r is not permitted Refer to User Manual in the relative chapter 7 1 for 3 instructions of cleaning and disinfection Do not have the oximeter immerged in liquid When it needs cleaning please wipe its s...

Page 6: ...able It is only necessary for patients to put one of his fingers into a probe for diagnosis and a display screen will directly show the measured value of pulse oxygen saturation with the high veracity...

Page 7: ...sitive element information acquired through which will be shown on screen through treatment in electronic circuits and microprocessor Figure 1 7 4 Technical specifications 4 1 Main performance A SpO2...

Page 8: ...nm 6 75mW 5 Installation 5 1 View of the front panel Figure 2 front view 5 2 Battery installation A Refer to Figure 3 and insert the two AAA size batteries properly in the right direction 9 B Replace...

Page 9: ...tion The icon of SpO2 is a program for receiving real time data which is shown as figure 5 the icon of SpO2 Review is a program for receiving stored data which is shown as figure 6 11 a Please connect...

Page 10: ...nds and then the screen will be automatically shut down only a flashing yellow dot appear on screen If short press the button at this moment the sign Recording would appear on the screen and then the...

Page 11: ...sensor should not be used at a location 15 or limb tied with arterial canal or blood pressure cuff or receiving intravenous injection E Do not fix the SpO2 sensor with adhesive or else it may result i...

Page 12: ...n shows C Take out the battery if leave the equipment unused for long time D The device needs to be calibrated once a year or according to the calibrating program of hospital It also can be performed...

Page 13: ...vice 1 Please change batteries 2 Please Install the battery again 3 Please contact the local service center The display is off suddenl y 1 The device s malfunction 2 The battery is drained away or alm...

Page 14: ...ion Specification Information Display Mode The Pulse Oxygen Saturation SpO2 2 digit digital OLED display Pulse Rate PR 3 digit digital OLED display Pulse Intensity bar graph bar graph OLED display SpO...

Page 15: ...Moving calculate the Average pulse rate every 4 cardio beat s cycle The deviation between average value and true value does not exceed 1 Safety Type Interior Battery Type 23 Pulse Intensity Range Con...

Page 16: ...24 Dimensions 58 5 L 31 W 32 H mm Weight About 50g with the batteries...

Page 17: ...File Ver 0 9 Release Date March 2009...

Reviews: