Appendix A: Example calculation
Calculation 1:
Calculating horizontal extension fig. 2a:
Flue length C + E = 1m + 1m
2 m
Elbows
D
=
2m
2
m
Total horizontal extension
4 m
Measure or calculate effective height (Hvert)
Flue length A
1 m
Roof
mounted
terminal
1
m
Total effective height
2 m
Always check if the calculated situation is allowed
(see appendix B: Flue restrictor)
Calculation 2:
Calculation horizontal extension fig. 2b:
Flue length J + L = 0,5 + 0,5
1 m
Elbows K + M = 2m + 2m
4 m
Terminal
1 m
Total horizontal extension
6 m
Calculation effective height (Hvert)
Flue
length
H
1
m
Always check if the calculated situation is allowed
(see appendix B: Flue restrictor)