Handing over (final check and customer briefing) 

ƒ

 

Instruct the customer on the full operation of the appliance and the remote control, 

including replacement of batteries 

ƒ

 

Advise the customer how to clean the appliance including the glass 

ƒ

 

Hand over these instructions including the user guide to the consumer 

ƒ

 

Recommend that the appliance should be serviced by a competent person at least 

once a year 

7

 

Servicing 

To ensure safe, efficient operation of the appliance, it is necessary to carry out routine 

servicing at regular intervals. 

It is recommended, that the fire is inspected/serviced by a competent person at least once a 

year. 

Important: Turn off the gas supply before commencing any servicing. Always test for gas 

soundness after refitting the appliance! 

7.1

 

Routine annual servicing 

ƒ

 

Clean (if necessary): 

a.

 

the pilot system 

b.

 

the burner 

c.

 

the combustion chamber 

d.

 

the glass 

ƒ

 

Check the log layout and replace the embers (if applicable) 

ƒ

 

Do the functional test as described in chapter 5 

ƒ

 

Check the flue system and terminal for damage and soundness (visual inspection) 

7.2

 

Cleaning the glass 

Depending on the intensity of use, you can get material deposits on the glass. Remove the 

glass (see chapter 4.3).  

Remove the deposit with a dry cloth or if necessary, special ceramic glass cleaner (ceramic 

hob cleaner).  

Attention: 

Make sure that the logs  have been placed correctly before fixing the glass. 

Before placing the glass: check the glass sealing rope is in good condition and makes an 

effective seal. Be sure that there are no fingerprints on the glass. It is not possible to 

remove those prints after you burn the appliance for a while (they are burnt in). Place the 

glass in front of the appliance and fix the glass frame or use the glass clamps. 

Summary of Contents for SERENE C11

Page 1: ...SERENE C11 EMOTION C11 INTENSE C11 Installation Guide IRL UK 40010716 0822...

Page 2: ...1 UK IRL Serene 1 1 1 2 1 3 1 4 1 5 C C C C B B B A A A D D...

Page 3: ...2 UK IRL Emotion Intense 2 1 2 2 2 3 2 4 D D C C E E A A A B B B...

Page 4: ...system 10 4 7 Placing the Log set 11 4 8 Placing the glass 11 4 9 Placing the Frame Serene 11 4 10 Placing the Frame Emotion Intense 11 5 Commissioning functional checks 12 5 1 Pilot ignition check 12...

Page 5: ...sired heights Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required Air supply and flue gases go to outside a...

Page 6: ...ns as amended the relevant British Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm...

Page 7: ...n combustible material e g Promatec do not place the lintel surround or marble stone directly onto the appliance If possible apply a lintel made of cement or something similar always ventilate the spa...

Page 8: ...t be fitted Terminals located close to shared walkways footpaths etc could be subject to legal constraints and this should be pointed out to the customer before installation If in any doubt about flue...

Page 9: ...s to be airtight The existing chimney needs to have an opening of min 150 x 150 mm The chimney needs to be intact and well looked after Use the adjustable roof mounted terminal especially made for thi...

Page 10: ...on chamber Place the right flue restrictor in the combustion chamber To determine the right flue restrictor see appendix A B 4 4 Placing the appliance in an existing chimney breast If possible first l...

Page 11: ...d makes an effective seal Be sure that there are no fingerprints on the glass It is not possible to remove those prints once they are burned in the glass o Place the glass in front of the appliance an...

Page 12: ...ng on the rear log See picture 4 how the logs should be positioned You are allowed to add different kind of embers on the burner tray to create your own ash bed 4 8 Placing the glass Be sure that ther...

Page 13: ...easuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pres...

Page 14: ...Routine annual servicing Clean if necessary a the pilot system b the burner c the combustion chamber d the glass Check the log layout and replace the embers if applicable Do the functional test as de...

Page 15: ...ne Rebuilding to another gas category is only possible by exchanging the complete burner plate Ask your local dealer and bring the serial number of the appliance A Pilot assembly B Burner C Fixation p...

Page 16: ...A 1 m Roof mounted terminal 1 m Total effective height 2 m Always check if the calculated situation is allowed see appendix B Flue restrictor Calculation 2 Calculation horizontal extension fig 2b Flue...

Page 17: ...the values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is pre installed Horizontal length m Serene C11 0 1 2 3 4 5 6 0 x x x x x x x 0 5 x 0 x x x x x 1 0...

Page 18: ...ficiency class 2 2 2 Inlet pressure mbar 20 30 37 Gas rate l h 618 183 213 Gas rate gram h Working pressure mbar 11 0 23 5 23 8 Injector size mm 3 x 1 40 3 x 0 85 3 x 0 85 Reduced input mm 1 6 1 0 1 0...

Page 19: ...18 UK IRL Appendix D Dimensions Serene...

Page 20: ...19 UK IRL Appendix E Dimensions Emotion...

Page 21: ...20 UK IRL Appendix F Dimensions Intense...

Page 22: ...21 UK IRL Appendix G Dimensions Convection grid...

Page 23: ...22 UK IRL...

Page 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501...

Reviews: