Introduction 

 

The appliance can only be installed by a 
competent person in accordance with the Gas 

Safety. We urgently advise you to read this 
installation manual properly. 

This appliance complies with the guidelines 
for European gas appliances (Gas Appliances 

Directive) and bears the CE mark. 
 

2

 

 Safety instructions. 

 

The appliance should be placed, 
connected and annually checked in 
accordance with these installation 

instructions and valid national and 
local Gas Safety (Installation and Use) 

Regulations . 

 

Check whether the data on the 

registration plate are in agreement 
with the local type of domestic gas 

and pressure.  

 

The fitter is not permitted to change 

these adjustments or the construction 
of the appliance! 

 

Do not place any additional imitation 
logs or glowing coals on the burner or 
in the combustion chamber. 

 

The appliance has been designed for 
ambience and heating purposes. This 

means that all surfaces of the 
appliance , including the glass, can 

become very hot (hotter than 100 
°C). An exception to this are the 

bottom  of the appliance and the 
controls. 

 

Do not  place any inflammable 
materials within a of  0.5 m. of the 

radiation of the appliance and 
ventilation grills.  

 

Due to natural air circulation of the 

appliance, moisture and volatile 
components from paint, building 

materials, floor coverings etc. that 
haven’t yet set, can be drawn through 

the convection system and can be 
deposited on cold surfaces as soot. 

That is why you should not use the 
appliance shortly after a renovation.   

 

The first time the appliance is 
switched on, Let the fire run on 

maximum setting for several hours so 
that the lacquer coating will have an 

opportunity to set and possible 
vapours released can be safely 

removed by ventilation. We advise 

you to be  outside the room as much 

as possible during this process! 

 

Please note that: 

 

all transport packaging should be 

removed.  

 

children or pets should not be 

present in the room. 

 

3

 

Installation requirements 

 

3.1

 

The fire  

 

The appliance must be built into an 
existing or a newly to be constructed 
false chimney breast. 

 

In appliances with flexible gas pipes, 
the gas control valve is mounted to 

the right side of the fire for safe 
transport . Unscrew it and mount it at 

a distance of max. 30  cm behind the 
access door. 

 

The receiver which has been attached 
in a transport holder (see fig. 1.3 A) 

to the side of control valve bracket, 
can now be slid onto the top of the 

control valve bracket. The transport 
holder can be removed now. 

3.2

 

False Chimney breast 

 

The false chimney breast must be 
constructed of an non-combustible 

material. 

 

Always ventilate the space above the 

appliance by means of the grills or a 
comparable alternative with a 

minimum air supply of 200 cm². 

 

For the finish, use special stucco 

(min. 100°C resistant) or glass fibre 
wallpaper to prevent discoloration or 

cracks etc. Recommended drying 
time: for plaster is a minimum of 24 

hours per mm of coat applied. 

 

The false chimney breast and its 
construction may not rest on the 

appliance  

3.3

 

 Requirements flue system and 

outlets 

 

You should always make use of the 

materials prescribed by Faber Only by 
using these materials can Faber  

guarantee a proper functioning. 

 

The outside of the concentric flue 

material can reach a temperature of  

 

Approx. 150°C. Make sure of proper 

isolation and protection in case of 

Summary of Contents for Respect OC

Page 1: ...Respect OC 40011335 1235 Installation manual ENG ENG ...

Page 2: ...1 L 1 1 1 2 1 3 1 4 2 1 2 2 2 3 A A A ...

Page 3: ...2 L 2 4 2 5 2 6 A B A C B ...

Page 4: ...3 L 3 1 3 2 3 3 3 4 3 5 3 6 ...

Page 5: ...4 L 3 7 A B ...

Page 6: ...5 L 4 1 4 2 4 3 A A A A A A ...

Page 7: ...the fire run on maximum setting for several hours so that the lacquer coating will have an opportunity to set and possible vapours released can be safely removed by ventilation We advise you to be outside the room as much as possible during this process Please note that all transport packaging should be removed children or pets should not be present in the room 3 Installation requirements 3 1 The ...

Page 8: ...ame if necessary and the glass and take the separately wrapped parts out of the appliance Prepare the gas connection to the gas control valve 4 4 Moving the appliance If necessary the upper parts of the appliance can be taken of this gives a minimum dimension of the appliance 780mm then the appliance can be transported on the back side see fig 2 1 It is only allowed to remove the transport plate a...

Page 9: ...build in frame The chimney construction may not resting on the build in frame 5 Placing the decorative material It is not allowed to add different or more materials to the combustion chamber Always keep the pilot burner and the second thermocouple free from decorative material See fig 4 1 A up to 4 3 A Do not toss all the decorative material onto the burner all at once it can be obstructed by dust...

Page 10: ...is on at full gas mark and when it is on the pilot light If the inlet pressure is too high you are not permitted to connect the appliance Measuring the burner pressure Only perform this measurement if the inlet pressure is correct Open the pressure gauge nipple A see fig 1 4 a few turns and connect a pressure gauge hose to the gas control valve The pressure must correspond with the value indicated...

Page 11: ...ters 9 Annual maintenance 9 1 Service and cleaning Check and clean if necessary after checking o The pilot light o The burner o The combustion chamber o The glass o The logs for possible fractures o The outlet 9 2 Replace o If necessary the chips embers o in an LPG flat burner replace the burner sheet 9 3 Cleaning the glass Most of the deposits can be removed with a dry cloth You can use ceramic h...

Page 12: ...s of the elements H J L M P and R fig 12 1 and 12 2 11 5 90 bends in the horizontal direction Only bends in the horizontal direction Indicated as I K and Q fig 12 1 12 2 and 12 3 11 6 45 of 30 bends in the horizontal direction Only bends in the horizontal direction 11 7 90 bends from vertical to horizontal direction 90 bends from vertical to horizontal direction or reversed Indicated as G O and S ...

Page 13: ...x x x x x 13 70 2 x x x x x x x x 14 70 2 x x x x x x x x 15 80 2 x x x x x x x x 16 80 2 x x x x x x x x 17 80 2 x x x x x x x x 18 80 2 x x x x x x x x 19 80 2 x x x x x x x x 20 80 2 x x x x x x x x 21 80 2 x x x x x x x x 22 80 2 x x x x x x x x 23 80 2 x x x x x x x x 24 80 2 x x x x x x x x 25 80 2 x x x x x x x x 26 80 2 x x x x x x x x 27 80 2 x x x x x x x x 28 80 2 x x x x x x x x 29 80 ...

Page 14: ...65 4 13 85 4 80 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 14 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 15 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 16 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 17 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 18 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 19 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 20 85 4 85 4 80 4 80 4 80 4 70 4 70 4 70 4 65 4 21 85 4 85 ...

Page 15: ...14 L 12 Example fig 12 1 fig 12 2 fig 12 3 ...

Page 16: ...om 2M or more 2 Bends 90 0 1 Bends 45 30 of 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL calculate Part number x value result rounded value Total length in meters x 1 90 bends vertical to horizontal x 0 4 45 bends vertical to horizontal x 0 2 90 bends in the horizontal direction x 1 5 45 bends horizontal dire...

Page 17: ...olution Start length to low see for the minimum length in the top row of the table Results Restrictor size Found value for the comma mm Extra information Found value behind the comma Mark which is applied Install the Air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of ro...

Page 18: ...bar gr h 1140 970 Burner pressure at full mark mbar 10 23 0 28 Injector main burner mm 7x0 89 7x1 09 7x0 54 7x0 61 7x0 54 7x0 61 Reduced input restraint mb Adjustable 4 4 Adjustable 14 3 Adjustable 17 Pilot assembly SIT 145 SIT 145 SIT 145 Code 36 23 23 Diameter inlet outlet mm 200 130 200 130 200 130 Gas control valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electrical connection V 220 220 220 B...

Page 19: ...18 L 15 Dimensions ...

Page 20: ...19 L ...

Page 21: ...20 L ...

Page 22: ...21 L ...

Page 23: ...22 L ...

Page 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 Dealer info ...

Reviews: