USE AND CARE CONTINUED - CONTROL PANEL

The hood can be operated from the control panel located on the right hand side of the hood or from 

the remote control. The FIGURE 11 is an illustration of the control panel.  The hood can be turned 

on by pushing any speed button T1 thru T4 directly.  

FIGURE 11

Turns lighting on and off.

First speed (press button)

When pressed for about 1 second, the motor is

switched off.

24 hour function 

(can operate all day and night to refresh 

and clean your home)

This is enabled by pressing the button for approximately 5 

seconds.  It operates at 60 cfm with a noise level of just .5 

sones. This function can be enabled at any speed, even with 

the hood turned off. To disable, press and hold the button for 

approximately 5 seconds.

Second speed (press button)

FUNCTIONS

GREEN LED

KEY

L    

0 / 1 Light

T1 

 0 / 1 Motor

T2

  Speed

T3 

 Speed

T4

  Speed

S1

  Red Led

ON

FLASHING

ON

FLASHING

ON

ON

FLASHING

ON

FLASHING

30 minute Delay Function

Press the button for 2 seconds to enable a 30 minute delay mode with automatic 

shut off. This function is used to eliminate any residual odors for 30 minutes. This 

can be enabled at any speed, even with the hood turned off and is disabled by 

pressing the Speed 1 (On/Off) button for one second.

Third speed (press button)

Max. speed (press button)

Intensive Boost Function

Use this function to eliminate the strongest cooking vapors and odors. Press the 

button for 2 seconds to enable the Intensive boost. After 10 minutes of intensive 

power, the motor turns off automatically. This function can be enabled from any 

speed even with the hood turned off, and is disabled by pressing any 

speed buttton.

Indicates that the Metal grease filter saturation alarm has

been triggered, and the filters need to be washed. The alarm

is triggered after 100 working hours. (To Reset; see the

Maintenance paragraph)

Indicates that the charcoal filter saturation

alarm has been triggered, and the filter has to be replaced;

the metal grease filters must also be washed. The

charcoal filter alarm is triggered after 200 working hours when using a ductless 

installation. (For Activation and to Reset; see the Maintenance paragraph)

Summary of Contents for MATRIX

Page 1: ...formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ B...

Page 2: ...eans to prevent power from being switched on accidentally Whentheservicedisconnectingmeanscannotbelocked securely fasten a prominent warning device such as a tag to the service panel CAUTION For Gener...

Page 3: ...s conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Ai...

Page 4: ...WS C DUCTLESS GRILLE D REAR DUCTING CHIMNEY TRANSITION E CHIMNEY VENT SCREWS F MOUNTING PLUGS G SAFETY SCREWS H GRILLE COVER I GRILLE COVER SCREWS J DAMPER A B C D E F G H I J TOOLS NEEDED FOR INSTALL...

Page 5: ...Version 09 05 Page 5 DUCTED INSTALLATION DIMENSIONS vented to the outside DUCTLESS INSTALLATION DIMENSIONS not vented to the outside...

Page 6: ...by pushing the lter forward and and pulling the handle down FIGURE 6 3 Adjustthetwoadjustingscrewsonthemountinghardware B in FIGURE 5 to the lowest point FIGURE 6 FOR ALL INSTALLATIONS 1 Remove the co...

Page 7: ...IGURE 9 WARRANTY SERVICE All Faber products are warranteed against any defect in ma terials or workmanship for the original purchaser for a period of 1 year from the date of original purchase This war...

Page 8: ...button for 2 seconds to enable a 30 minute delay mode with automatic shut off This function is used to eliminate any residual odors for 30 minutes This can be enabled at any speed even with the hood t...

Page 9: ...he ducting panels Charcoal Filter Alarm Activation The lter alarm has to be activated in order to use with ductless installations which use the charcoal lters The alarm can be activated upon installat...

Page 10: ...ENT IF NEEDED FUSE Model 5 X 20 5A time delay 1 Remove the lters 2 Remove the screws xing the fuseholder box 3 Open the fuseholder bayonet xing 4 Replace the fuse with another of the same type 5 Repla...

Page 11: ...is 1 1 4 po Ciseaux Pinces Tournevis Phillips Tournevis lame plate D nude l ou couteau tout usage Pince coupante l m tallique Ruban mesurer ou r gle Niveau Crayon Outil calfeutrage Ruban conduit PI CE...

Page 12: ...Version 09 05 Page 12 DIMENSIONS D INSTALLATION AVEC CONDUIT DIMENSIONS D INSTALLATION SANS CONDUIT...

Page 13: ...z les 4 panneaux de la hotte en glissant les chevilles de xation Sch ma 5 A 2 Avec les deux mains enlever les ltres graisse un la fois en poussant le ltre et en tirant la poign e vers le bas Sch ma 6...

Page 14: ...URE 9 GARANTIE ET SERVICE Fabergarantit l utilisateur acheteurd originequelesproduits Faber vendus neufs par nous sont sans vice de mat riel et de main d oeuvre d origine pour une p riode d un an part...

Page 15: ...enir l option de mise en marche diff r e de 30 secondes avec arr t automatique Cette fonction est utilis e pour liminer les odeurs r siduelles pendant 30 minutes Peut tre utilis e n importe quelle vit...

Page 16: ...rer les vieux ltres charbon et les remplacer par des neufs Replacer alors les ltres graisse en m tal et fermer les panneaux de conduit Activation De L alarme Des Filtres Au Charbon L alarme de ltre do...

Page 17: ...od le 5X20 5A 1 Enlever les ltres 2 Enlever les vis en xant le boite porte fusibles 3 Ouvrir le porte fusibles 4 Remplacer le fusible avec un autre du meme mod le 5 Remplacer la boite porte fusible et...

Reviews: