PREPARE  THE  WALL

1. 

Disconnect and move freestanding range from cabinet open-

ing to provide easier access to rear wall.  Put a thick, protective 

covering over cooktop, set-in range or countertop to protect from 

damage or dirt.

2. 

Determine and clearly mark with a pencil the center line on the 

wall where the rangehood will be installed.

3.

 Draw a horizontal line at 43" above the cooktop

 (as indicated 

in FIGURE 4). 

Mark two points (1) 

(in FIGURE 4)

 on the horizontal 

line, 7 7/8" away from the center line on each side.  Make sure both 

marks are level.

4. Mark two points (2)

 (in FIGURE 4) 

which are 19 7/16" above 

the cooktop, and are 7 1/16" on either side of the center line. Make 

sure both marks are level.        

FIGURE 5

5.

 In holes (1) 

(in FIGURE 4) 

attach the two mounting brackets 

(B) to the wall with 2 mounting screws. 

6. In holes (2) 

(in FIGURE 4) 

put one safety screw (G) in each 

hole, do not tighten the screws all the way.

B

F

G

FIGURE 4

INSTALL  THE  RANGEHOOD

1. 

Open the ducting panels on the rangehood. Disconnect 

the 4 panels from the hood by sliding the fixing pin lever

 (as 

indicated in (A) FIGURE 5).  

2. Using two hands, remove the grease filters one at a time 

by  pushing  the  filter  forward  and  and  pulling  the  handle 

down. 

(FIGURE 6) 

3. Adjust the two adjusting screws on the mounting hardware 

(B in FIGURE 5)

 to the lowest point

FIGURE 6

FOR ALL INSTALLATIONS

1. 

Remove the cover from the Field Wiring Compartment with 

a phillips screwdriver.  Feed the Power Supply Cable through 

the electrical knockout.  Connect the Power Supply Cable to the 

rangehood cable.  Attach the Power Supply Cable grounding 

lead to the green screw provided.  Attach the White lead of the 

power supply to the White lead of the rangehood with a twist-on 

type wire connector.  Attach the Black lead of the power supply 

to the Black lead of the rangehood with a twist-on type wire 

connector.  Using the 4 holes provided screw the Field Wiring 

Compartment to the wall as dictated by your Power Supply 

Cable location (screws not provided).  Replace the cover.

WARNING:  THE SCREWS PROVIDED FOR MOUNTING THIS 

RANGEHOOD MUST BE INSERTED INTO SOLID WOOD.  THESE 

MUST NOT BE INSERTED INTO SHEET ROCK.

4. Hang the rangehood on the two mounting screws and 

from the inside of the hood, adjust the mounting screws to 

make the hood level 

(B in FIGURE 5)

5. Tighten the safety screws

 (Hole 2, in FIGURE 4)

6. 

For ducted installations, the DAMPER

 (J in FIGURE  1) 

must be attached to the exhaust opening at the top of the 

CANOPY  SECTION.  Connect  the  ductwork  and  seal  all 

connections with duct tape.

15"

19 7/16

"

43

"

Summary of Contents for MATRIX

Page 1: ...formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ B...

Page 2: ...eans to prevent power from being switched on accidentally Whentheservicedisconnectingmeanscannotbelocked securely fasten a prominent warning device such as a tag to the service panel CAUTION For Gener...

Page 3: ...s conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Ai...

Page 4: ...WS C DUCTLESS GRILLE D REAR DUCTING CHIMNEY TRANSITION E CHIMNEY VENT SCREWS F MOUNTING PLUGS G SAFETY SCREWS H GRILLE COVER I GRILLE COVER SCREWS J DAMPER A B C D E F G H I J TOOLS NEEDED FOR INSTALL...

Page 5: ...Version 09 05 Page 5 DUCTED INSTALLATION DIMENSIONS vented to the outside DUCTLESS INSTALLATION DIMENSIONS not vented to the outside...

Page 6: ...by pushing the lter forward and and pulling the handle down FIGURE 6 3 Adjustthetwoadjustingscrewsonthemountinghardware B in FIGURE 5 to the lowest point FIGURE 6 FOR ALL INSTALLATIONS 1 Remove the co...

Page 7: ...IGURE 9 WARRANTY SERVICE All Faber products are warranteed against any defect in ma terials or workmanship for the original purchaser for a period of 1 year from the date of original purchase This war...

Page 8: ...button for 2 seconds to enable a 30 minute delay mode with automatic shut off This function is used to eliminate any residual odors for 30 minutes This can be enabled at any speed even with the hood t...

Page 9: ...he ducting panels Charcoal Filter Alarm Activation The lter alarm has to be activated in order to use with ductless installations which use the charcoal lters The alarm can be activated upon installat...

Page 10: ...ENT IF NEEDED FUSE Model 5 X 20 5A time delay 1 Remove the lters 2 Remove the screws xing the fuseholder box 3 Open the fuseholder bayonet xing 4 Replace the fuse with another of the same type 5 Repla...

Page 11: ...is 1 1 4 po Ciseaux Pinces Tournevis Phillips Tournevis lame plate D nude l ou couteau tout usage Pince coupante l m tallique Ruban mesurer ou r gle Niveau Crayon Outil calfeutrage Ruban conduit PI CE...

Page 12: ...Version 09 05 Page 12 DIMENSIONS D INSTALLATION AVEC CONDUIT DIMENSIONS D INSTALLATION SANS CONDUIT...

Page 13: ...z les 4 panneaux de la hotte en glissant les chevilles de xation Sch ma 5 A 2 Avec les deux mains enlever les ltres graisse un la fois en poussant le ltre et en tirant la poign e vers le bas Sch ma 6...

Page 14: ...URE 9 GARANTIE ET SERVICE Fabergarantit l utilisateur acheteurd originequelesproduits Faber vendus neufs par nous sont sans vice de mat riel et de main d oeuvre d origine pour une p riode d un an part...

Page 15: ...enir l option de mise en marche diff r e de 30 secondes avec arr t automatique Cette fonction est utilis e pour liminer les odeurs r siduelles pendant 30 minutes Peut tre utilis e n importe quelle vit...

Page 16: ...rer les vieux ltres charbon et les remplacer par des neufs Replacer alors les ltres graisse en m tal et fermer les panneaux de conduit Activation De L alarme Des Filtres Au Charbon L alarme de ltre do...

Page 17: ...od le 5X20 5A 1 Enlever les ltres 2 Enlever les vis en xant le boite porte fusibles 3 Ouvrir le porte fusibles 4 Remplacer le fusible avec un autre du meme mod le 5 Remplacer la boite porte fusible et...

Reviews: