Faber MATRIX Installation Instructions Manual Download Page 7

Version 09/05 - Page 7

DUCTED INSTALLATIONS

FIGURE 7

1. 

For rear ducted installations, attach the rear chimney 

transition to the top of the rangehood

 (FIGURE 7) 

with the 

4 screws provided.  

2. If installing the hood with ductwork venting up thru the 

ceiling (not to the rear of the hood thru the wall ) , then the 

optional  chimney  covers  (purchased  separately)  can  be 

attached over the ductwork. Please call 508-358-5353 for 

instructions on attaching chimney covers.

FIGURE 8

C

E

H

I

DUCTLESS INSTALLATIONS

1. 

Screw the ductless grille to the top duct with 4 screws 

 

(part C using the E screws in FIGURE 8)

.  

2. Attach the grille cover (H in FIGURE 7) using the cover 

screws 

(I in FIGURE 8).

 

3. Attach one charcoal filter to each end of the blower.  Each 

charcoal filter attaches to the grid on the side of the blower.  

Rotate the filter clockwise to install and counterclockwise to 

remove 

(as indicated in FIGURE 9).

  

FOR ALL INSTALLATIONS

1. 

Install the grease filters 

(as indicated in FIGURE 6)

  

2. Place the 4 ducting panels back onto the hood 

(as indicated in FIGURE 5)

3. Turn the power supply on. Turn on blower and lights. If the 

rangehood does not operate, check that the circuit breaker 

is not tripped or the house fuse blown. If the unit still does 

not operate, disconnect the power supply and check that the 

wiring connections have been made properly. 

FIGURE 9

WARRANTY  &  SERVICE

All Faber products are warranteed against any defect in ma-

terials or workmanship for the original purchaser for a period 

of 1 year from the date of original purchase.  This warranty 

covers labor and replacement parts.  The warranty does not 

cover consumable parts such as filters and light bulbs.  This 

warranty does not apply if this product has been subjected to 

faulty installation, misuse, or neglect.  This warranty excludes 

any consequential expense or damage resulting from any 

use or malfunction of the product.  All implied warranties are 

limited to the duration of this warranty. 

To obtain warranty service, contact the dealer from whom you 

purchased the rangehood, or the local Faber distributor.  If you 

cannot identify a local Faber distributor, contact us at (508) 

358-5353 for the name of a distributor in your area.

USE  AND  CARE  INFORMATION

This rangehood system is designed to remove smoke, cooking 

vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop 

proper airflow.  Allow the unit to operate for several minutes 

after cooking is complete to clear all smoke and odors from the 

kitchen.

Remote Control

The rangehood can be controlled using the enclosed remote 

control which has the same control layout 

(as indicated in 

FIGURE 11).  

The remote uses alkaline AAA type batteries.  To 

replace the batteries, remove the cover by removing the screw 

and sliding off the cover 

(as indicated in FIGURE 10).  Do not 

place the remote control close to heat sources.  

FIGURE 10

Summary of Contents for MATRIX

Page 1: ...formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ B...

Page 2: ...eans to prevent power from being switched on accidentally Whentheservicedisconnectingmeanscannotbelocked securely fasten a prominent warning device such as a tag to the service panel CAUTION For Gener...

Page 3: ...s conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Ai...

Page 4: ...WS C DUCTLESS GRILLE D REAR DUCTING CHIMNEY TRANSITION E CHIMNEY VENT SCREWS F MOUNTING PLUGS G SAFETY SCREWS H GRILLE COVER I GRILLE COVER SCREWS J DAMPER A B C D E F G H I J TOOLS NEEDED FOR INSTALL...

Page 5: ...Version 09 05 Page 5 DUCTED INSTALLATION DIMENSIONS vented to the outside DUCTLESS INSTALLATION DIMENSIONS not vented to the outside...

Page 6: ...by pushing the lter forward and and pulling the handle down FIGURE 6 3 Adjustthetwoadjustingscrewsonthemountinghardware B in FIGURE 5 to the lowest point FIGURE 6 FOR ALL INSTALLATIONS 1 Remove the co...

Page 7: ...IGURE 9 WARRANTY SERVICE All Faber products are warranteed against any defect in ma terials or workmanship for the original purchaser for a period of 1 year from the date of original purchase This war...

Page 8: ...button for 2 seconds to enable a 30 minute delay mode with automatic shut off This function is used to eliminate any residual odors for 30 minutes This can be enabled at any speed even with the hood t...

Page 9: ...he ducting panels Charcoal Filter Alarm Activation The lter alarm has to be activated in order to use with ductless installations which use the charcoal lters The alarm can be activated upon installat...

Page 10: ...ENT IF NEEDED FUSE Model 5 X 20 5A time delay 1 Remove the lters 2 Remove the screws xing the fuseholder box 3 Open the fuseholder bayonet xing 4 Replace the fuse with another of the same type 5 Repla...

Page 11: ...is 1 1 4 po Ciseaux Pinces Tournevis Phillips Tournevis lame plate D nude l ou couteau tout usage Pince coupante l m tallique Ruban mesurer ou r gle Niveau Crayon Outil calfeutrage Ruban conduit PI CE...

Page 12: ...Version 09 05 Page 12 DIMENSIONS D INSTALLATION AVEC CONDUIT DIMENSIONS D INSTALLATION SANS CONDUIT...

Page 13: ...z les 4 panneaux de la hotte en glissant les chevilles de xation Sch ma 5 A 2 Avec les deux mains enlever les ltres graisse un la fois en poussant le ltre et en tirant la poign e vers le bas Sch ma 6...

Page 14: ...URE 9 GARANTIE ET SERVICE Fabergarantit l utilisateur acheteurd originequelesproduits Faber vendus neufs par nous sont sans vice de mat riel et de main d oeuvre d origine pour une p riode d un an part...

Page 15: ...enir l option de mise en marche diff r e de 30 secondes avec arr t automatique Cette fonction est utilis e pour liminer les odeurs r siduelles pendant 30 minutes Peut tre utilis e n importe quelle vit...

Page 16: ...rer les vieux ltres charbon et les remplacer par des neufs Replacer alors les ltres graisse en m tal et fermer les panneaux de conduit Activation De L alarme Des Filtres Au Charbon L alarme de ltre do...

Page 17: ...od le 5X20 5A 1 Enlever les ltres 2 Enlever les vis en xant le boite porte fusibles 3 Ouvrir le porte fusibles 4 Remplacer le fusible avec un autre du meme mod le 5 Remplacer la boite porte fusible et...

Reviews: