16
Cleaning metal grease filters
The metal grease filters can be cleaned in hot detergent solution
or washed in the dishwasher. They should be cleaned every 2
months, or more frequently if use is particularly heavy.
•
Remove the filter, pushing the lever towards the back of the
unit and at the same time pulling downward.
•
Wash the filter without bending it, leave it to dry thoroughly
before replacing (if the surface of the filter changes color
over time, this will have absolutely no effect on its efficiency).
• Replace, taking care to ensure that the handle faces
forward.
•
Cleaning in dishwasher may dull the finish of the metal
grease filter.
•
No water can be present in filters before installing
back in hood.
Replacing Activated Charcoal Filter
The Activated Charcoal Filters are not washable and cannot
be regenerated, and should be replaced approximately
every 4 months of operation, or more frequently with heavy
usage.
•
Remove the charcoal filter by rotating it clockwise (backwards) until
it unlocks from the motor housing and pull off sideways.
•
To re-insert each charcoal filter, place up against the side
of the blower and push it inward. Then turn the charcoal
filter clockwise (forward) until it fits into place.
Caution
:
"When used in recirculation mode, to Reduce
the Risk of Fire and Shock use only conversion kit Model
FILTER 1 or FILTER1LL"
EN
77
INSTALLATION
Fitting the Hood canopy
BEFORE FITTING THE HOOD TO THE WALL UNIT, PROCEED AS FOLLOWS:
• Disconnect the wires to the Commands at the connectors.
• Disconnect the wires to the Light at the con-
nectors.
• The Hood can be installed directly on the
underside of the wall unit (Minimum 650 mm
from the Cooker Hob).
• Create an opening in the bottom of the wall unit,
as shown.
• Insert the hood until the side supports snap into
place.
• Fasten using the 10 screws
12a
provided.
• Lock in position by tightening the screws
Vf
from
underneath the hood.
• Open the suction panel by turning the specific knob.
• Disconnect the panel from the hood canopy by sliding the
fixing pin lever.
• Remove grease filters.
• Screw the Frame into place
using the 6 screws
12f
, re-
connect the wires to the
Commands and Light, re-
place the metal grease filter
and the Panel.
260
13
495 - 675
Gu10 self-ballasted led lamps
– listed in accordance with ul
1993/nmx-j-578/1-ance/csa
c22.2 No. 1993
a
b
a
b
Lighting unit
• Replace the lamp with a new one of the
same type, making sure that you insert the
two pins properly into the housings on the
lamp holder.
Summary of Contents for INHC29SSV
Page 5: ...5 RANGEHOOD DIMENSIONS REAR RANGEHOOD DIMENSIONS DRAFT 06 NOV 2018 12 04 INHC29SSV INHC35SSV...
Page 6: ...6 Min 24 Min 30...
Page 17: ...17 Wiring Diagram 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 22: ...22 DIMENSIONS DE LA HOTTE DIMENSIONS DE LA HOTTE DRAFT 06 NOV 2018 12 04 INHC29SSV INHC35SSV...
Page 23: ...23 Min 24 Min 30...
Page 34: ...34 Sch ma de c blage 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 40: ...40 Min 24 Min 30...
Page 51: ...51 Diagrama de cableado 991 0530 011 H90 503 D00004494_00 120V 60Hz...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...