10
3.b
2
1/2
”
>
For horizontal(rear) ducting there
must be a minimum of 2 1/2" of
space open between the back of the
Hood Insert and the wall.
For a horizontal ducting installation
the motor needs to be unsecured
by first removing the 12 screws as
shown.
Once the screws are removed,
extract the blower from the body of
the Insert Hood and position it so the
transition opening is facing to the
rear wall (from the back remove and
rotate 180 degrees to the left, and
then flip it back 90 degrees as shown
in the diagram).
Once the blower is in place re-install
the 12 screws to fasten the motor to
the Insert Hood body.
Rear Ducting Installation
[
[