Annual maintenance
9.1
Service and cleaning:
Check and clean if necessary after checking:
o
The pilot light
o
The burner (in an LPG flat burner replace the burner sheet)
o
The combustion chamber
o
The glass
o
The logs for possible fractures
o
The outlet
9.2
Replace:
o
(in an LPG flat burner replace the burner sheet)
o
If necessary the chips/embers.
9.3
Cleaning the glass
Most of the deposits can be removed with a dry cloth. You can use ceramic hob cleaner to
clean the glass.
Note: prevent fingerprints on the glass. these will be burned into it once the appliance is
used and cannot be removed anymore!
Carry-out the check-up according to the instructions in chapter 7 “checking the
installation”
10
Conversion to a different type of gas (e.g.
propane)
This can only be done by installing the proper burner unit. for this purpose get in touch
with your supplier.
Always mention the type and serial number of the appliance when ordering.