27
Module Solenoid Valve Replacement
Tools Required:
Short Phillips head screwdriver
1. Follow the Preparing for Service instructions. (Page 11)
2. Remove the fill cap by turning it clockwise.
3. Remove the top cover assembly by gently pushing the tabs on both sides until they snap in place. (Figure 14)
4. Disconnect the tranducer(s), and lift out the water reservoir.
5. Locate the solenoid valve to be replaced. (Figure 24)
6. Trace and disconnect the control wire for the solenoid back to the main control board.
7. Remove the two screws from the front face of the bracket to release the valve. (Figure 25)
8. Disconnect the plumbing connections and remove the solenoid valve.
9. Run new wire through to main control board.
10. Install new solenoid valve.
11. Reconnect the control wire.
12. Reinsert the water reservoir, transducer, top cover assembly, and fill cap.
13. Re-assemble the remainder of the components in reverse order from the Preparing for Service instructions. (Page 11
Figure 24
Replacement Part Procedures
Solenoid Valve
Solenoid