INSTRUCTION BOOKL: PELLET STOVE FOR LOCAL AIR HEATING .
DESIGN INNOVATION SUSTAINABILITY FUNCTIONALITY HIGH PERFORMANCE
77/80
Cause
Possible Solutions
Ambient and gas
temperatures described
on the control panel do
not make sense
Bad connection of the temperature probes to the board.
Check connections
Probe short-circuited. Replace
The control panel is
illegible
Control panel damaged. Replace
Cables incorrectly connected. Check the electrical cable
connections. Replace.
The stove does not switch
on
Check that the stove is plugged in and on the button on the
back.
Fuses damaged. Replace
Cables incorrectly connected. Check the electrical cable
connections.
Others:
Technical Failures (continued)