background image

2

2

1

1

2

2

2

5

3

4

6

6

RX

RX

TX

TX

7

a

b

c

d

e

f

g

1113

750

311

85

85

119

S450H

ENGLISH

1  DESCRIPTION AND TECHNICAL SPECIFICATIONS

1.1  DIMENSIONS

a

  Front fitting

b

  Cover

c

  Emergency release with key

d

  Plastic cover for rear bracket

e

  Rear bracket

f

  Encoder

g

  Spacer for opening mechanical stop

TECHNICAL

SPECIFICATIONS

CBAC

OPERATOR

SB 

OPERATOR

Power supply (V dc)

24 - 36

Power consumption (W)

60 (nominal) - 288 (maximum)

Protection class

IP 55

Oil type

FAAC HP OIL

Operating temperature

-20°C +50°C

R.O.T. (24V) 

Continuous at 55°C

Hydraulic lock

Installed

Not installed

Traction/thrust force

max (N) 

5000 (E124) - 3600 (E024S)

Max. opening angle

See table 1

Max. leaf length (m) 

2

3

Rod linear speed (Cm/s) 

2,5 (E124) - 2,0 (E024S)

Effective rod stroke (mm)

311

Operator weight (kg)

7.1

6.9

2  PRESETTINGS

RX

  Photocells (receiver) 

 

(TRADITIONAL: 4 x 0.5 mm²; 2easy bus: 2 x 0.5 mm²)

TX

  Photocells (transmitter)  

(2 x 0.5 mm²)

c

 

Electronic control unit 

 

(power supply 3 x 1.5 mm²)

d

 

Key-operated push-button (e.g. T11) (3 x 0.5 mm²)

e

 

Flashing lamp 24 V dc (2 x 1 mm²)

f

 

Opening mechanical stops*  

 

g

 

Electric lock and closing mechanical stop 

 

(2 x 1.5 mm)

3  INSTALLATION OF THE AUTOMATED SYSTEM

Following conditions have to be met to ensure safety and the 
efficient operation of the automated system:
• The gate structure must be suitable for automation. Verify in 
particular that it is sufficiently strong and stiff and that dimensions 
and  weight  correspond  to  those  stated  in  the  technical 
specifications.
• Verify the smooth and uniform movement of leaves, without 
irregular friction during the whole travel.
• Verify the good condition of hinges.
• Verify the presence of mechanical limit switches.
• Remove any locks and bolts.
Carry  out  any  metalwork  operations  before  installing  the 
automated system.

Fig. 1

Fig. 2

The FAAC S450H automated system for swing-leaf gates consists 
of an electrical pump and an hydraulic piston transmitting the 
leaf movement, assembled in a single block.
The model with hydraulic lock can automate leaves up to 2 m. 
It does not require the installation of electric locks and guaran-
tees that the leaf is mechanically locked when the motor is not 
in  operation.  The  model  without  hydraulic  lock  always  needs 
one or more electric locks to guarantee the leaf mechanical 
lock. 

The S450H  automated  systems  have  been  designed 

and built to automate swing-leaf gates. Avoid any other use 
whatever.
Without  encoder  the  automated  system  does  not  operate 
correctly.

Fig. 3

Dimensions in millimeters

*  CONSIDERING  40  bar  (E124)  30  bar  (E024)  STATIC  PRESSURE 
ON PISTONE
**  CONSIDERING  A  RANGE  OF  PUMP  1.5  lpm  (E124)  AND  1.2 
lpm (E024S)

 

a

DISTANCE (m)

20 m

35 m

50 m

ø

  MOTOR CABLE

2x2.5 mm²

2x4 mm²

2x6 mm²

ø

 2 easy bus  

ENCODER CABLE

2x0.5 mm² 2x0.5 mm² 2x0.5 mm²

Summary of Contents for S450H

Page 1: ...S450H...

Page 2: ...e safety devices EN 12978 protect from the hazards caused by mechanical movements such as crushing entrapment and shearing hazards 17 Each installation should be fitted with at least one flashing ligh...

Page 3: ...tructure must be suitable for automation Verify in particular that it is sufficiently strong and stiff and that dimensions and weight correspond to those stated in the technical specifications Verify...

Page 4: ...2 XXX 115 1 110 1 a B ENGLISH ATTENTION do not cut for any reason the rear bracket Make reference to figures 4 and 5 and to table 1 to determine the installation position of the operator INSTALLATION...

Page 5: ...3 205 214 90 1 90 1 90 2 90 2 90 2 90 3 90 3 215 224 90 1 89 2 90 2 90 2 90 2 90 3 90 3 Z a 3 a 2 D1 a 1 3 2 1 TAB 2 B1 XXX XXXX D1 XXX 115 1 115 1 XXX 110 2 110 2 XXX 100 3 100 3 B1 50 75 100 85 1060...

Page 6: ...ear fitting to the pillar or fix it by means of suitable screws dowels threaded inserts Observe the dimensions stated in Tab 1 never cut the rear fitting moreover it must be installed with the word UP...

Page 7: ...used Fig 1 re g Remove the front articulated joint and insert on the rod the number of spacers required to reach the desired opening angle Fig 14 10 11 12 13 14 If an external mechanical stop point a...

Page 8: ...g during leaf movement Leaf stationary DL 1 must always be ON to ensure the right connection between encoder and board DL 2 indicates the leaf where the encoder is installed If the encoder is installe...

Page 9: ...F 1 VERIFY THAT THE LEDS DL1 AND DL2 ARE ON WHEN THE MOTOR IS NOT IN OPERATION LEAF 1 TWO LEDS ON THROUGH THE BRACKET COVER OF LEAF 2 VERIFY THAT THE LED DL1 IS ON WHEN THE MOTOR IS NOT IN OPERATION L...

Page 10: ...g that must remain it its seat Remove all spacers if present Fig 25 4 Tilt the operator upward as much as possible D o n o t f o r c e t h e r e a r f i t t i n g t o o m u c h 5 Supply the operator w...

Page 11: ...in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der v...

Reviews: