background image

MiniTIME

 

SA:

 

Installation

 

Guide

 

and

 

User

 

Guide

  

Pag.

 

7

 

C

OMANDO

 

D

ESCRIZIONE

 

D

EFAULT

 

E

SEMPIO

 

10#

F

E

 

Wiegand/MagStripe

 

Interface

 

F

 

=

 

1

 → 

Wiegand,

  

F

 

=

 

0

 → 

MagStripe

 

MagStripe

 

 

 

 

 

5.7

 

Menu

 

8

 

 

Internal/External

 

reader

 

activation

 

To

 

enter

 

the

 

menu

 

read

 

paragraph

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

C

OMANDO

 

D

ESCRIZIONE

 

C

OMANDO

 

D

ESCRIZIONE

 

1#1E

 

Enable

 

RF

 

module

 

for

 

passive

 

cards

 

(Default)

 

1#0E

 

Disable

 

RF

 

module

 

for

 

passive

 

cards

 

2#1E

 

Enables

 

Reader

 

B

 

2#0E

 

Disables

 

Reader

 

B

 

(Default)

 

 

5.8

 

Special

 

Commands

 

These

 

commands

 

can

 

only

 

be

 

managed

 

from

 

outside

 

the

 

configuration

 

menu.

 

In

 

the

 

following

 

tab

 

MC

 

indicates

 

the

 

Master

Code.

 

C

OMANDO

 

D

ESCRIZIONE

 

C

OMANDO

 

D

ESCRIZIONE

 

65000#

MC

 

All

 

Absent

 

65001#

MC

 

All

 

present

 

65300#

MC

 

Reset

 

titles

 

archive

 

65301#

MC

 

Reset

 

settings

 

65534#

MC

 

Reset

 

Master

Code

 

(a

 

new

 

one

 

is

 

needed)

 

65535#

MC

 

Reset

 

to

 

Default

 

The

 

#

 

key

 

can

 

be

 

omitted

 

when

 

a

 

“Master

Card”

 

is

 

used.

 

 

6

 

Reset

 

Functions

 

Reset

 

Functions

 

are

 

particularly

 

helpful

 

when

 

the

 

“anti

pass

back”

 

features

 

are

 

used.

 

These

 

Fuctions

 

enable

 

the

 

user

 

to

 

set

 

the

 

status

 

of

 

all

 

the

 

titles

 

to

 

a

 

specific

 

value.

 

The

 

reset

 

1

 

function

 

enables

 

the

 

MINITIME

SA

 

to

 

consider

 

all

 

the

 

titles

 

as

 

absent

 

(all

 

titles

 

are

 

out

 

the

 

controlled

 

area).

 

The

 

feature

 

is

 

activated

 

upon

 

using

 

a

 

card

 

or

 

by

 

code

 

imput

 

on

 

the

 

keyboard

  

of

 

any

 

of

 

the

 

readers.

 

The

 

reset

 

2

 

function

 

has

 

a

 

similiar

 

function:

 

this

 

function

 

can

 

take

 

place

 

in

 

two

 

ways,

 

it

 

enables

 

the

 

MINITIME

SA

 

to

 

consider

 

all

 

the

 

titles

 

as

 

absent

 

or

 

present,

 

depending

 

on

 

which

 

reader

 

is

 

used

 

for

 

the

 

operation:

 

if

 

the

 

code/card

 

is

 

used

 

on

 

an

 

entrance

 

reader

 

all

 

titles

 

will

 

be

 

considered

 

present,

 

if

 

it

 

is

 

used

 

on

 

an

 

exit

 

reader

 

all

 

the

 

titles

 

will

 

be

 

considered

 

absent.

 

 

7

 

Note

 

dell’Installatore

 

 

 

Summary of Contents for MiniTIME SA

Page 1: ...Product Line MiniTIME SA FAAC S p A Via Benini 1 40069 Zola Predosa BO ...

Page 2: ...5 Settings 4 5 1 Menu 1 Inserting a user code card 4 5 2 Menu 2 Deleting a user code card 4 5 3 Menu 3 Activating a user code card 5 5 4 Menu 4 5 Data Import Export 5 5 5 Menu 6 I O Configuration 6 5 6 Menu 7 Reader B Configuration 6 5 7 Menu 8 Internal External reader activation 7 5 8 Special Commands 7 6 Reset Functions 7 7 Note dell Installatore 7 Pag 2 ...

Page 3: ...e provides an anti tempering contact it manages the alarm contact special care has to be provided by positioning the device in a protected zone and by putting a reader head outside the reader not an automatic decision making device Figure 2 Links 2 Links In Figure 2 please note the internal side of the device where the 4 connectors are indicated On the card only the J7 and J9 connectors are presen...

Page 4: ...and for last the master code Once this is done the device will on a steady amber LED To exit a setting menu it is necessary to press and hold the key for more than 4 seconds alternatively the user can insert a master code master card Menù Tipo di Programmazione Menù Tipo di Programmazione 1 Inserting a user code card 5 Data Export 2 Deleting a user code card 6 I O Configuration 3 Activating a user...

Page 5: ...ead on B does not command the exit 1 K 1 a read on B commands the exit 2 K 0 a read on B does not command the exit 1 7 1100E 7 0011E 7 1010E 7 0101E 7 1001E 7 0110E 7 0000E Title 7 opens A and B if read on A Title 7 opens A and B if read on B Title 7 opens A if read by A and B Title 7 opens B if read by A and B Title 7 opens A of read by A Opens B if read by B Title 7 opens B if read by A Opens A ...

Page 6: ...rical cross management F 0 Disabled F 1 Enabled 0 6 FE Gate open door contact logic F 1 NC F 0 NA NA 7 FE Gate status contact logic F 1 NC F 0 NA NA 8 FE tamper logic F 1 NC F 0 NA NA 5 6 Menu 7 Reader B Configuration To enter the menu read paragraph Errore L origine riferimento non è stata trovata Errore L origine riferimento non è stata trovata In the following tab TTT indicates a number between...

Page 7: ...les archive 65301 MC Reset settings 65534 MC Reset Master Code a new one is needed 65535 MC Reset to Default The key can be omitted when a Master Card is used 6 Reset Functions Reset Functions are particularly helpful when the anti pass back features are used These Fuctions enable the user to set the status of all the titles to a specific value The reset 1 function enables the MINITIME SA to consi...