background image

MiniTIME

 

SA:

 

Installation

 

Guide

 

and

 

User

 

Guide

  

5.3

 

Menu

 

3

 

 

Activating

 

a

 

user

 

code

 

/

 

card

 

This

 

function

 

enables

 

to

 

user

 

to

 

change

 

the

 

access

 

configurations

 

for

 

either

 

a

 

single

 

user

 

or

 

a

 

group

 

of

 

locations.

 

For

 

every

 

title

 

it’s

 

possible

 

to

 

set

 

the

 

gate

 

and

 

“direction”

 

(absent/present),

 

it

 

is

 

also

 

possible

 

to

 

enable

 

the

 

anti

 

pass

 

back

 

check.

 

To

 

enter

 

the

 

menu

 

read

 

paragraph

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

T

IPO

 

DI

 

COMANDO

 

D

ESCRIZIONE

 

NNN#CE

 

Executes

 

the

 

C

 

command

 

on

 

the

 

NNN

 

location

 

NNN#FFF#CE

 

Executes

 

the

 

C

 

command

 

on

 

the

 

FFF

 

location

 

1111#CE

 

Executes

 

the

 

C

 

command

 

on

 

all

 

the

 

locations.

 

 

C

OMANDO

 

D

ESCRIZIONE

 

E

SEMPIO

 

5

 

Forces

 

the

 

“absent”

 

status

 

37#5E

 

Title

 

37

 

Absent

 

6

 

Forces

 

the

 

“present”

 

status

 

116#6E

 

Title

 

115

 

Present

 

7

 

Enables

 

the

 

“Anti

 

PASS

BACK”

 

check

 

21#7E

 

Title

 

21

 

enabled

 

with

 

Anti

 

PASS

BACK

 

check

 

8

 

Disables

 

the

 

“Anti

 

PASS

BACK”

 

check

 

3#8E

 

Title

 

3

 

not

 

enabled

 

with

 

Anti

 

PASS

BACK

 

check

 

GHJK

 

The

 

configuration

 

is

 

changed

 

for

 

both

 

A

 

and

 

B

 

readers

 

G

 

=

 

1:

 

a

 

read

 

on

 

A

 

commands

 

the

 

exit

 

1

 

G

 

=

 

0:

 

a

 

read

 

on

 

A

 

does

 

not

 

command

 

the

 

exit

 

1

 

H

 

=

 

1:

 

a

 

read

 

on

 

A

 

commands

 

the

 

exit

 

2

 

H

 

=

 

0:

 

a

 

read

 

on

 

A

 

does

 

not

 

command

 

the

 

exit

 

2

 

J

 

=

 

1:

 

a

 

read

 

on

 

B

 

commands

 

the

 

exit

 

1

 

J

 

=

 

0:

 

a

 

read

 

on

 

B

 

does

 

not

 

command

 

the

 

exit

 

1

 

K

 

=

 

1:

 

a

 

read

 

on

 

B

 

commands

 

the

 

exit

 

2

 

K

 

=

 

0:

 

a

 

read

 

on

 

B

 

does

 

not

 

command

 

the

 

exit

 

1

 

7#1100E

 

7#0011E

 

7#1010E

 

7#0101E

 

7#1001E

 

 

7#0110E

 

 

7#0000E

 

 

Title

 

7

 

opens

 

A

 

and

 

B

 

if

 

read

 

on

 

A

 

Title

 

7

 

opens

 

A

 

and

 

B

 

if

 

read

 

on

 

B

 

Title

 

7

 

opens

 

A

 

if

 

read

 

by

 

A

 

and

 

B

 

Title

 

7

 

opens

 

B

 

if

 

read

 

by

 

A

 

and

 

B

 

Title

 

7

 

opens

 

A

 

of

 

read

 

by

 

A

  

 

Opens

 

B

 

if

 

read

 

by

 

B

 

Title

 

7

 

opens

 

B

 

if

 

read

 

by

 

A

  

 

Opens

 

A

 

if

 

read

 

by

 

B

 

Title

 

7

 

disabled

 

GH

 

The

 

configuration

 

is

 

changed

 

on

 

reader

 

A

 

G

 

=

 

1:

 

a

 

read

 

on

 

A

 

commands

 

exit

 

1

 

G

 

=

 

0:

 

a

 

read

 

on

 

A

 

does

 

not

 

command

 

exit

 

1

 

H

 

=

 

1:

 

a

 

read

 

on

 

A

 

commands

 

exit

 

2

 

H

 

=

 

0:

 

a

 

read

 

on

 

A

 

does

 

not

 

command

 

exit

 

2

 

9#00E

 

9#01E

 

9#10E

 

9#11E

 

Title

 

9

 

disabled

 

Title

 

9

 

opens

 

B

 

if

 

read

 

by

 

A

 

Title

 

9

 

opens

 

A

 

if

 

read

 

by

 

A

 

Title

 

9

 

opens

 

A

 

and

 

B

 

if

 

read

 

by

 

A

 

NOTE:

 

the

 

A

 

reader

 

is

 

the

 

automatic

 

decision

making

 

reader.

 

The

 

reader

 

B

 

is

 

the

 

remote

 

reader

 

which

 

does

 

not

 

have

 

the

 

“automatic

 

decision

making”

 

feature.

 

 

 

 

 

5.4

 

Menu

 

4/5

 

 

Data

 

Import/Export

 

To

 

enter

 

the

 

menu

 

read

 

paragraph

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

The

 

menu

 

n.

 

4

 

is

 

used

 

for

 

importing

 

data,

 

the

 

menu

 

5

 

is

 

used

 

for

 

exporting

 

data.

 

These

 

menus

 

are

 

used

 

for

 

saving

 

the

 

settings

 

and

 

the

 

codes

 

whenever

 

a

 

backup

 

or

 

an

 

export

 

operation

 

is

 

needed.

 

C

OMANDO

 

D

ESCRIZIONE

 

C

OMANDO

 

D

ESCRIZIONE

 

1E

 

Complete

 

Import/Export

 

2E

 

Settings

 

and

 

Codes

 

import/Export

 

3E

 

Codes

 

Import/Export

 

4E

 

Settings

 

Import/Export

 

 

Pag.

 

5

 

Summary of Contents for MiniTIME SA

Page 1: ...Product Line MiniTIME SA FAAC S p A Via Benini 1 40069 Zola Predosa BO ...

Page 2: ...5 Settings 4 5 1 Menu 1 Inserting a user code card 4 5 2 Menu 2 Deleting a user code card 4 5 3 Menu 3 Activating a user code card 5 5 4 Menu 4 5 Data Import Export 5 5 5 Menu 6 I O Configuration 6 5 6 Menu 7 Reader B Configuration 6 5 7 Menu 8 Internal External reader activation 7 5 8 Special Commands 7 6 Reset Functions 7 7 Note dell Installatore 7 Pag 2 ...

Page 3: ...e provides an anti tempering contact it manages the alarm contact special care has to be provided by positioning the device in a protected zone and by putting a reader head outside the reader not an automatic decision making device Figure 2 Links 2 Links In Figure 2 please note the internal side of the device where the 4 connectors are indicated On the card only the J7 and J9 connectors are presen...

Page 4: ...and for last the master code Once this is done the device will on a steady amber LED To exit a setting menu it is necessary to press and hold the key for more than 4 seconds alternatively the user can insert a master code master card Menù Tipo di Programmazione Menù Tipo di Programmazione 1 Inserting a user code card 5 Data Export 2 Deleting a user code card 6 I O Configuration 3 Activating a user...

Page 5: ...ead on B does not command the exit 1 K 1 a read on B commands the exit 2 K 0 a read on B does not command the exit 1 7 1100E 7 0011E 7 1010E 7 0101E 7 1001E 7 0110E 7 0000E Title 7 opens A and B if read on A Title 7 opens A and B if read on B Title 7 opens A if read by A and B Title 7 opens B if read by A and B Title 7 opens A of read by A Opens B if read by B Title 7 opens B if read by A Opens A ...

Page 6: ...rical cross management F 0 Disabled F 1 Enabled 0 6 FE Gate open door contact logic F 1 NC F 0 NA NA 7 FE Gate status contact logic F 1 NC F 0 NA NA 8 FE tamper logic F 1 NC F 0 NA NA 5 6 Menu 7 Reader B Configuration To enter the menu read paragraph Errore L origine riferimento non è stata trovata Errore L origine riferimento non è stata trovata In the following tab TTT indicates a number between...

Page 7: ...les archive 65301 MC Reset settings 65534 MC Reset Master Code a new one is needed 65535 MC Reset to Default The key can be omitted when a Master Card is used 6 Reset Functions Reset Functions are particularly helpful when the anti pass back features are used These Fuctions enable the user to set the status of all the titles to a specific value The reset 1 function enables the MINITIME SA to consi...

Reviews: