background image

MiniTIME

 

SA:

 

Installation

 

Guide

 

and

 

User

 

Guide

  

4

 

Operative

 

Modes

 

On

 

the

 

activation

 

of

 

the

 

MINITIME

SA

 

the

 

device

 

verifies

 

the

 

presence

 

of

 

a

 

MASTER

 

CODE.

 

If

 

this

 

cose

 

is

 

not

 

set,

 

the

 

system

 

will

 

wait

 

for

 

this

 

code

 

to

 

be

 

set.

 

This

 

situation

 

can

 

be

 

identified

 

by

 

the

 

fact

 

the

 

all

 

the

 

lights

 

of

 

the

 

device

 

blink

 

rythmically.

 

To

 

proceed

 

it

 

is

 

necessary

 

to

 

insert

 

a

 

master

 

code,

 

in

 

detail

 

it

 

is

 

necessary

 

to

 

use

 

a

 

card

 

that

 

will

 

work

 

as

 

MASTER

 

CODE.

  

If

 

the

 

Master

 

Code

 

is

 

already

 

present

 

upon

 

the

 

activation,

 

the

 

system

 

will

 

work

 

in

 

access

 

control

 

mode

 

(AC

 

mode).

 

The

 

system

 

is

 

on

 

permament

 

waiting

 

for

 

a

 

valid

 

title,

 

both

 

on

 

A

 

and

 

B

 

readers

 

(if

 

reader

 

B

 

is

 

activated).

 

This

 

title

 

can

 

be

 

either

 

a

 

card

 

or

 

a

 

keyboard

 

code,

 

if

 

the

 

title

 

is

 

not

 

valid

 

the

 

system

 

will

 

emit

 

a

 

single

 

sound

 

and

 

a

 

yellow

 

LED

 

will

 

turn

 

on.

 

If

 

the

 

title

 

is

 

valid,

 

the

 

device

 

will

 

emit

 

2

 

sounds

 

and

 

will

 

turn

 

on

 

the

 

green

 

LED,

 

after

 

this

 

the

 

system

 

will

 

open

 

the

 

programmed

 

gate.

 

To

 

configure

 

all

 

the

 

system

 

parameters

 

it’s

 

necessary

 

to

 

use

 

one

 

of

 

the

 

methods

 

described

 

below.

 

 

4.1

 

Funzionamento

 

Tastiera

 

The

 

Keyboard

 

is

 

touch

sensitive.

 

It

 

is

 

not

 

necessary

 

to

 

exert

 

a

 

pressure

 

on

 

the

 

keyboard.

 

When

 

the

 

#

 

key

 

is

 

pressed,

 

the

 

device

 

will

 

delete

 

the

 

last

 

inserted

 

character.

 

If

 

the

 

#

 

key

 

is

 

activated

 

twice

 

the

 

whole

 

code

 

will

 

be

 

deleted.

 

The

 

E

 

key

 

will

 

act

 

as

 

a

 

confirmation

 

key.

 

 

5

 

Settings

 

The

 

parameters

 

settings

 

are

 

divided

 

into

 

8

 

menus.

 

To

 

have

 

access

 

to

 

the

 

menù

 

the

 

user

 

has

 

to

 

insert

 

the

 

menu

 

number,

 

followed

 

by

 

the

 

master

card/#

 

key

 

and

 

for

 

last

 

the

 

master

 

code.

 

Once

 

this

 

is

 

done,

 

the

 

device

 

will

 

on

 

a

 

steady

 

amber

 

LED.

 

To

 

exit

 

a

 

setting

 

menu

 

it

 

is

 

necessary

 

to

 

press

 

and

 

hold

 

the

 

#

 

key

 

for

 

more

 

than

 

4

 

seconds,

 

alternatively

 

the

 

user

 

can

 

insert

 

a

 

master

 

code

 

/

 

master

 

card.

 

Menù

 

Tipo

 

di

 

Programmazione

 

Menù

 

Tipo

 

di

 

Programmazione

 

1

 

Inserting

 

a

 

user

 

code

 

/

 

card.

 

5

 

Data

 

Export

 

2

 

Deleting

 

a

 

user

 

code

 

/

 

card.

 

6

 

I/O

 

Configuration

 

3

 

Activating

 

a

 

user

 

code

 

/

 

card.

 

7

 

Reader

 

B

 

configuration

 

4

 

Data

 

Import

 

8

 

Readers

 

activation.

 

 

 

5.1

 

Menu

 

1

 

 

Inserting

 

a

 

user

 

code

 

/

 

card

 

Consider

 

that

 

for

 

every

 

user

 

title

 

it

 

is

 

necessary

 

to

 

specify

 

the

 

memory

 

location/cell.

 

These

 

go

 

from

 

1

 

to

 

500

 

and

 

every

 

cell

 

can

 

contain

 

a

 

maximum

 

of

 

1

 

title.

 

It’s

 

a

 

good

 

idea

 

to

 

keep

 

up

 

a

 

scheme

 

with

 

the

 

titles

 

locations.

 

To

 

enter

 

the

 

menu

 

read

 

paragraph

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

To

 

insert

 

proceed

 

to

 

digit

 

the

 

location

 

number.

 

If

 

the

 

user

 

wants

 

to

 

use

 

a

 

keyboard,

 

press

 

the

 

#

 

key

 

and

 

insert

 

the

 

code,

 

otherwise

 

use

 

a

 

title

 

on

 

one

 

of

 

the

 

readers.

 

If

 

the

 

procedure

 

ends

 

well

 

the

 

system

 

will

 

emit

 

a

 

steady

 

alternating

 

sound

 

with

 

the

 

green

 

LED

 

blinking.

 

If

 

the

 

procedure

 

doesn’t

 

end

 

correctly

 

the

 

system

 

will

 

emit

 

a

 

fast

 

paced

 

alternated

 

sound

 

along

 

with

 

the

 

amber

 

blinking

 

LED.

 

EXAMPLE:

 

To

 

insert

 

the

 

key

 

code

 

347683

 

in

 

position

 

39,

 

the

 

code

 

will

 

be

 

39#347683E.

 

To

 

insert

 

a

 

title

 

in

 

position

 

392

 

it’s

 

enough

 

to

 

insert

 

the

 

392

 

code

 

followed

 

by

 

the

 

code.

 

 

5.2

 

Menu

 

2

 

 

Deleting

 

a

 

user

 

code

 

/

 

card

 

To

 

enter

 

the

 

menu

 

read

 

paragraph

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

 

Errore.

 

L'origine

 

riferimento

 

non

 

è

 

stata

 

trovata.

 

To

 

delete

 

a

 

user

 

card

 

/

 

code

 

it’s

 

enough

 

to

 

insert

 

the

 

location

 

and

 

press

 

the

 

E

 

key.

 

 

 

 

Pag.

 

4

 

Summary of Contents for MiniTIME SA

Page 1: ...Product Line MiniTIME SA FAAC S p A Via Benini 1 40069 Zola Predosa BO ...

Page 2: ...5 Settings 4 5 1 Menu 1 Inserting a user code card 4 5 2 Menu 2 Deleting a user code card 4 5 3 Menu 3 Activating a user code card 5 5 4 Menu 4 5 Data Import Export 5 5 5 Menu 6 I O Configuration 6 5 6 Menu 7 Reader B Configuration 6 5 7 Menu 8 Internal External reader activation 7 5 8 Special Commands 7 6 Reset Functions 7 7 Note dell Installatore 7 Pag 2 ...

Page 3: ...e provides an anti tempering contact it manages the alarm contact special care has to be provided by positioning the device in a protected zone and by putting a reader head outside the reader not an automatic decision making device Figure 2 Links 2 Links In Figure 2 please note the internal side of the device where the 4 connectors are indicated On the card only the J7 and J9 connectors are presen...

Page 4: ...and for last the master code Once this is done the device will on a steady amber LED To exit a setting menu it is necessary to press and hold the key for more than 4 seconds alternatively the user can insert a master code master card Menù Tipo di Programmazione Menù Tipo di Programmazione 1 Inserting a user code card 5 Data Export 2 Deleting a user code card 6 I O Configuration 3 Activating a user...

Page 5: ...ead on B does not command the exit 1 K 1 a read on B commands the exit 2 K 0 a read on B does not command the exit 1 7 1100E 7 0011E 7 1010E 7 0101E 7 1001E 7 0110E 7 0000E Title 7 opens A and B if read on A Title 7 opens A and B if read on B Title 7 opens A if read by A and B Title 7 opens B if read by A and B Title 7 opens A of read by A Opens B if read by B Title 7 opens B if read by A Opens A ...

Page 6: ...rical cross management F 0 Disabled F 1 Enabled 0 6 FE Gate open door contact logic F 1 NC F 0 NA NA 7 FE Gate status contact logic F 1 NC F 0 NA NA 8 FE tamper logic F 1 NC F 0 NA NA 5 6 Menu 7 Reader B Configuration To enter the menu read paragraph Errore L origine riferimento non è stata trovata Errore L origine riferimento non è stata trovata In the following tab TTT indicates a number between...

Page 7: ...les archive 65301 MC Reset settings 65534 MC Reset Master Code a new one is needed 65535 MC Reset to Default The key can be omitted when a Master Card is used 6 Reset Functions Reset Functions are particularly helpful when the anti pass back features are used These Fuctions enable the user to set the status of all the titles to a specific value The reset 1 function enables the MINITIME SA to consi...

Reviews: