![background image](http://html.mh-extra.com/html/faac/minitime-sa/minitime-sa_installation-manual-and-user-manual_535600003.webp)
MiniTIME
SA:
Installation
Guide
and
User
Guide
Figure
1:External
View
1
Product
The
MiniTime
‐
SA
is
an
access
control
device
which
is
able
to
store
codes
and
card
autonomously.
The
central
can
store
a
MASTER
‐
CODE
(code
or
card)
and
500
user
codes
(keyboard
codes
or
cards).
The
MASTER
‐
CODE
length,
if
inserted
as
a
keyboard
code
has
to
be
between
6
and
14
characters.
The
User
Codes
lenght
(if
inserted
trough
keyboard)
has
to
be
between
4
and
14
charaters.
If
the
keyboard
is
not
present
a
special
12
cards
kit
has
to
be
used
(optional
kit:
“passive
SA
cards
kit”).
These
cards
emulate
a
12
key
keyboard
(numbers
from
0
to
9
plus
#
and
E
keys).
PLEASE
NOTE:
The
device
carries
the
command
contact
which
are
activated
with
a
valid
card/code.
Even
if
the
device
provides
an
anti
‐
tempering
contact
(it
manages
the
alarm
contact)
special
care
has
to
be
provided
by
positioning
the
device
in
a
protected
zone
and
by
putting
a
reader
head
outside
the
reader
(not
an
automatic
decision
‐
making
device).
Figure
2:
Links
2
Links
In
Figure
2
please
note
the
internal
side
of
the
device
where
the
4
connectors
are
indicated.
On
the
card
only
the
J7
and
J9
connectors
are
present.
Figure
3:
J7
Connection
Figure
4:
J9
Connection
3
Caratteristiche
Elettriche
Min
Max
Unit
Note
Power
Supply
12
24
V
Both
AC
and
DC
Consumption
Vin
=
12Vdc
Vin
=
24Vdc
Vin
=
16Vac
120
100
115
mA
Reader
B
not
connected
Maximum
releis
contact
tension
60
125
Vdc
Vac
Maximum
current
per
impedence
charge
V
=
150Vac
V
=
24Vdc
V
=
60Vdc
0.5
1
0.3
A
Alarm
output
current
70
mA
Alarm
output
tension
(open
circuit)
14
V
Current
Reader
B’s
buzzer
50
mA
Alarm
output
tension
(open
circuit)
14
V
Input
tension
for
DOOR
STATUS
/
OPEN
DOOR,
CLK
and
DATA.
‐
15
24
V
Pag.
3