3.4 TROUBLESHOOTING
The indications below will help you locate and solve particular conditions.
CONDITION
ADVICE
The bollard does not rise, it remains down.
Make sure you have selected the default no. 6 on the JE275 board
Check if the wiring of the solenoid valve was performed correctly, see par. 9
Check the electrical wiring of the motor
The bollard remains up in closed position.
Make sure nothing between the cylinder and the sliding bush prevents the bollard movement
Check the electrical wiring of the motor
The LED flashing lamp does not operate
Make sure you have selected the default no. 6 on the JE275 board
Check if the power connector under the head was fitted correctly.
4. PERFORMING MAINTENANCE ON THE EFO SYSTEM
!
The EFO system tank is always under pressure. Before carrying out any maintenance operation, to avoid potentially dangerous situations, the circuit
must be discharged before any other operation.
The bollard is rapidly closed when the EFO is activated. Clear the relative area from objects and people in order to prevent dangerous situations
To discharge the EFO, activate the system by opening the contact between terminals 7 and 8 of the terminal board (EFO N.O.) or supplying
voltage to the solenoid valve via the same terminals (EFO N.C.), then
slowly
unscrew the screws in figure 15, ref.