3
4
J275 HA 2K20
8
532270 - Rev.A
1245
1175
525
275
610
550
Tr
ansla
tion of the original instruc
tions
ENGLISH
OPTIONAL ACCESSORIES
Emergency lowering device
(solenoid valve)
Obstacle detection device
(pressure switch)
Cover
2
Technical data
Power supply voltage
230 V ~ 50 Hz
Max power
575 W
Max force
2500 N
Pump delivery
3 l/min
Lifting time
~ 8 s
Lowering time
~ 4.5 s
Ambient operating temperature
-15 °C to +55 °C
Ambient operating temperature (with optional heater)
-40 °C to +55 °C
Type of use
Intensive
Bollard weight
160 kg
Pit weight
80 kg
Cylinder height
800 mm
Cylinder diameter
275 mm
Oil quantity
1.5 l
Oil type
FAAC HP OIL
Protection rating
IP56
Hydraulic control unit protection rating
IP67
Dimensions
See
4
Thrust capacitor (pre-wired)
16 μF - 400V
Continuous use time (ROT)
110 min at 23°C
Load class (EN124)
C250 (25 t)
3.8 DIMENSIONAL DRAWING