9
10
11
12
J275 HA 2K20
11
532270 - Rev.A
5
8
T30
10
45 Nm
1
3
2
2
1
24
90 Nm
Tr
ansla
tion of the original instruc
tions
ENGLISH
9. Remove the eyebolts and fasten the bollard to the pit using the ten
M12x30 screws and the eight M16x30 screws. Apply the fastening
torques given in
9.
10. Fasten the cover to the frame using the eight M6x20 screws.
To reposition or lift the cover, prise one of the two slots upwards using
a screwdriver.
5.2 MANUAL OPERATION
!
Before carrying out the release procedure, disconnect the power supply
to the automation system.
RELEASE PROCEDURE
1.
11
Remove the plugs
1
and unscrew the screws
2
.
2. Unscrew the plug
3
.
3.
12
Insert the key
1
and turn it anticlockwise until it stops
2
.