- Power supply: battery pack with six LR20 alkaline

batteries sealed in series

- Consumption in surveillance status: 300 µA max.
- Average consumption in alarm status: < 1.15 A
- Average consumption in emission status: < 50 mA
- Time range: 30 months under normal use

conditions

- Acoustic power at 1m: 109 dB +/- 2 dB
- Modulation: C 48-465 standard
- Self-protection: opening and housebreaking
- Signals:

ƒ

alarm: 90 secs.

ƒ

discharged batteries: indicated by a series of
acoustic signals and by sending radio information
to the control unit

- Control unit / siren radio range:

ƒ

free field: from 200 to 300 m according to
environment

ƒ

indoor: according to environment

- Radio communication: two-way
- Radio frequencies: 434 and 868 MHz band
- Enclosure: ABS-PC
- Operating temperature: -25°C / +70°C
- Dimensions: 277 x 188 x 100 mm
- Weight: 2.75 kg (including battery pack)

TEST

- Press the control unit's 

“Test”

push-button (green).

The siren will sound for 1.5 seconds to confirm the
test.
Every pressure on the push-button will re-enable the
test.

TECHNICAL
SPECIFICATIONS

The siren must be powered and recognised by
the control unit (learning).

The control unit must be in MAINTENANCE
PROGRAM mode (battery compartment open).

- To return to normal operation: close al the

system's elements (control unit last of all).

Another way of running a siren test:

- Press the “ON” key on the remote control for more

than five seconds, or enter programming on the
control keypad (after inputting the access code)
and select the “Warning Signal Test” menu.

AP

EFF

TEST

Passage open signal

Peripheral units fault
/Telephone line fault

Discharged batteries

Run the system general test, consulting the control
unit instructions.

If activated, the siren is sounded for 

90 secs.

To stop the siren sound:
- Press the “OFF” key of the remote control, or

disable the alarm from the control keyboard.

Important:

the siren measures the outdoor

temperature. If there are several sirens in the same

system, the “C5” component of
the additional sirens must be
cut out so that the control
keypad carries out a single
temperature measurement.

- Close the siren door and fasten the screws

The siren is ready for
operation

5

7

6

Note:

the outdoor siren signals the enabling and

disabling of surveillance,
emitting respectively one and
two short beeps. This option
can be disabled by cutting out
component C7.

C5 C6 C7 C8

C5 C6 C7 C8

C5 C6 C7 C8

C5 C6 C7 C8

C5 C6 C7 C8

C5 C6 C7 C8

C5 C6 C7 C8

Summary of Contents for HSE

Page 1: ...Installation and use instructions HSE HSL Outdoor radio siren ...

Page 2: ...2 CONTENTS 1 Presentation 3 2 Preparation 3 3 Power supply 3 4 Learning 4 5 Installation 4 Drilling template 6 Test 5 7 Technical specifications 5 CE Declaration 6 Notes 7 PAGE ...

Page 3: ...or open o siren not secured will trip the siren sound after 4 minutes This time period is sufficient to close the siren 2 1 Discharged batteries indication Discharged batteries are indicated at every ON OFF operation by a series of acoustic signals We advise you to put the discharged batteries in the appropriate collection bins We therefore advise you to test radio transmission before definitively...

Page 4: ... screws for about four turns Using the drilling template supplied with the instructions Place a screw in front of the self protection rocker The screw must project by about 20 mm so that the rocker can rest on it inside the siren Secure the siren enclosure 20 mm self protection rocker wall Remember to use one of the screws supplied in the bag The screw head must be between 18 and 20 mm from the wa...

Page 5: ...Drilling template detach this ...

Page 6: ...20 mm Tip 6 mm diameter 16 4 mm 40 5 mm 124 mm 122 mm 233 5 mm TOP Wall height of screw C A B C 188 mm 277 mm DRILLING TEMPLATE Outdoor radio siren Scale 1 1 ...

Page 7: ...Drill all the holes A B C D 2 Insert screws A and B for 2 3rds of their length 3 Insert screw C observing the indicated height 4 Position the enclosure and insert screw D 5 Check if the rocker rests on the head of screw C ...

Page 8: ...Drilling template detach this ...

Page 9: ...control unit must be in MAINTENANCE PROGRAM mode battery compartment open To return to normal operation close al the system s elements control unit last of all Another way of running a siren test Press the ON key on the remote control for more than five seconds or enter programming on the control keypad after inputting the access code and select the Warning Signal Test menu AP EFF TEST Passage ope...

Page 10: ...l safety NF EN 60950 October 2000 TBTS device class III Electromagnetic compatibility EN 301489_3 July 2000 NF EN 50130_4 April 1995 A1 1998 Effective use of the radioelectric spectrum EN 300 220_3 V1 1 1 September 2000 It is declared that the essential radio tests were performed The CE mark is affixed to the product Year when CE mark was affixed 2004 Constructor s CE Declaration No 04 011 _1 Bolo...

Page 11: ...7 NOTES ...

Page 12: ...llustrations in this manual are not binding While leaving the essential characteristics of the equipment unaltered FAAC reserves the right at any time and without having to update this publication to make the modifications which it considers convenient for technical improvements or for any other construction or commercial requirements ...

Reviews: