background image

12

 

 

 

ENGLISH

 

7.    To  use  radiocontrols  with the  same  code,   copy  the 

ON - OFF combination  to  the  other  radiocontrols 
without the  need  to  change   anything  on  the  control 
board.

 

 

6.2  STORING  SLH RADIOCONTROLS

 

It  is   possible to  store  a  maximum   of

 

256  codes  divided  between  OPEN  A and

 

OPEN B/CLOSE.

 

1.    On the SLH radiocontrol,  press and  hold down P1 and    1.

 

P2 simultaneously.

 

2.    The radiocontrol  led will begin  to flash.

 

3.    Release both  push-buttons.

 

4.    Press  and  hold  down  push-button 

(SW3)  or 

(SW2)  2. 

and  then  press  the  SETUP  push-button  (SW4),  to  store  

3. 

total  opening  (OPEN  A) or  partial  opening  (OPEN  B/

 

CLOSE) respectively. The corresponding  led will begin

 

to flash slowly for 5 secs. 

4.

 

5.    Release both  push-buttons.

 

6.    Within this 5 sec. period while the radiocontrol led is still

 

flashing,  press and hold down the required push-button   

5. 

on the radiocontrol  (the radiocontrol  led will come  on

 

with a fixed light).

 

7.    The corresponding  led  will come  on with a fixed light

 

6.3  STORING LC/RC  RADIOCONTROLS 

(ONLY FOR SOME  MARKETS)

 

It  is   possible to  store  a  maximum   of

 

256  codes  divided  between  OPEN  A and

 

OPEN B/CLOSE.

 

 

Use the LC/RC remote  controls only with a

 

433  MHz receiving module.

 

Press  and  hold  down  push-button 

(SW3)  or 

(SW2) 

and  then  press  the  SETUP  push-button  (SW4),  to  store 
total  opening   (OPEN  A) or  partial  opening   (OPEN  B/ 
CLOSE)  respectively. The  corresponding  led  will  begin 
to flash slowly for 5 secs.

 

Release the push-button.

 

Within this 5 second  period,  press the required  push- 
button  on the LC/RC remote  control.

 

The led  will come   on  with a  fixed light for 1 second, 
indicating  that  the  unit  has  been  stored,  and  then 
resume  flashing for an  additional   5  seconds  during 
which time  another radiocontrol  may  be  stored. 
Once the 5 seconds are up, the led will go off to indi- 
cate  that the procedure  is complete.

 

 

6.3.1 STORING LC/RC RADIOCONTROLS REMOTELY

 

for 2 seconds  and  then go  off to indicate  the setting 
has been  stored.

 

8.    Release the radiocontrol  push-button.

 

With LC/RC radiocontrols,  other  radiocontrols  may  be 
stored in remote  mode,  i.e. without operating  directly  on 
the board,  using a previously stored radiocontrol.

 

9.    Press the stored radiocontrol push-button twice in quick   1. 

succession.

 

The automated   system will carry  out  an  

2.

 

   

opening  control.  Ensure the  automated

 

device  is  free  of  any  obstacle  by  people  

3.

 

or things.

 

 

To enable  other radiocontrols with the same system code,    

4. 

transfer the system code  of the stored radiocontrol  push-

 

button to the corresponding  push-button of the radiocon- 
trols to be  added, following the procedure  below:

 

5.

 

Obtain  a  radiocontrol  already  stored  on  one  of  its

 

2 channels  (OPEN A or OPEN B/CLOSE).

 

Press and  hold  down  push-buttons P1 and  P2 simulta- 
neously until both  leds flash slowly for 5 secs.

 

Within 5 seconds, push the previously stored radiocon- 
trol push-button  to activate  the  learning stage  on  the 
selected  channel.

 

The  led  on  the  board  corresponding  to  the  channel 
being  stored flashes for 5 seconds,  within which  time 
the code  of another radiocontrol  must be  sent.

 

The led  will come   on  with a  fixed light for 1 second,

 

a.    On the stored radiocontrol,  press and  hold  down

 

P1 and  P2 simultaneously.

 

b.    The radiocontrol  led will begin  to flash. 
c.    Release both  push-buttons.

 

d.    Press  the  stored push-button  and  hold  down  (the 

radiocontrol  led will come  on with a fixed light).

 

e.    Bring the radiocontrols closer to one another, press 

and  hold down  the corresponding  push-button  of 
the radiocontrol  to be  added, releasing only once 
the  led  on  the  radiocontrol  has issued a  double 
flash to indicate  that it has been  stored.

 

indicating   that  the  unit  has  been  stored,  and  then 
resume  flashing  for  an  additional   5  seconds  during 
which  time  other  radiocontrols  may  be  stored  and 
then it will go  off.

 

 

6.4 RADIOCONTROLS DELETION PROCEDURE

 

To  delete   

ALL 

the  codes  of  the  radiocontrols  entered, 

simply press down  together  the two push-buttons 

(SW3) 

and 

(SW2),  then  press the  SETUP  push-button  (SW4)  for

 

1 second,  and  hold the first two push-buttons pressed for

 

10 secs.

 

f.     Press the stored radiocontrol  push-button twice in  

 

quick succession.

 

 

The automated   system will carry  out  an

 

opening  control.  Ensure the  automated  

 

device  is  free  of  any  obstacle  by  people

 

or things.

 

The 2  leds  RADIO1  and  RADIO2  will flash quickly  for

 

10 secs.

 

The 2 leds will come  on with a fixed light for 2 seconds 
and  then go  off (deletion carried  out).

 

Release both  push-buttons.

 

 

This operation is NOT reversible.  All the codes 
of the  radiocontrols  stored as OPEN  A and 
as OPEN B/CLOSE will be deleted.

 

Summary of Contents for Estate Swing E-SL 1800

Page 1: ...E SL 1800...

Page 2: ...N 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above must be observed in addition to nation al legal regulations 11 Before attempting any job o...

Page 3: ...ATION 6 5 4 INSTALLING THE RACK 7 5 4 1 STEEL RACK TO WELD Fig 11 7 5 4 3 NYLON RACK TO SCREW Fig 13 7 5 4 2 STEEL RACK TO SCREW Fig 12 7 6 OPERATIONAL START UP 8 6 1 ELECTRONIC BOARD CONNECTION 8 6 1...

Page 4: ...ergency batteries are not installed or if the operator is not in service These operators in addition to having different features and technical specifications also differ as to the following compo nen...

Page 5: ...to be automated an upper guide must be provided plus mechanical limit switches to pre vent the gate derailing The gate slide track must be linear and horizontal Manual movement of the gate must be eas...

Page 6: ...h as shown in Fig 7 and wall in the founda tion plate supplying one or more sheaths for routing electric cables through the hole in the foundation plate Using a spirit level check if the plate is perf...

Page 7: ...hough openings in the motor casing see Fig 9 re 1 Fig 8 and Fig 9 refer to operator C720 E SL1800 3 Adjust the height of the gearmotor and the distance from the gate with reference to the dimensions i...

Page 8: ...e slot In this way the slot play will enable any adjustments to be made 3 Mark the drilling point on the gate Drill a 1 4 in hole and apply thread with a 3 8 in male tap Screw the bolt 4 Move the gate...

Page 9: ...on the control board connections programming mainte nance always turn off power Observe points 10 11 12 13 14 of the GENERAL SAFETY OBLIGATIONS Follow the instructions in Fig 3 to arrange the cables i...

Page 10: ...t be left from the mechanical limit switches 7 TESTING THE AUTOMATED SYSTEM Once the operator has been installed carry out a thorough oper ational check of all accessories and connected safety devices...

Page 11: ...e which must comply with current standards and of the release devices 10 REPAIR Contact an authorized Repair Centre for repairs 11 ACCESSORIES 11 1 BATTERY KIT Install the battery kit as shown in Fig...

Page 12: ...the gate re closes by itself after the selected pause time If semi automatic operating mode has been selected a second pulse must be sent to re close the gate An opening pulse issued during the re cl...

Page 13: ...RELEASE BATTERY E E7 72 20 BUS 2EASY F OPEN A GND OPEN B CLOSE SAFE STOP SAFE FSW OP GND FSW CL 24 RADIO XF SETUP USB OUT...

Page 14: ...RORS 15 10 FUNCTION LOGICS 16 EC DECLARATION OF CONFORMITY Manufacturer FAAC S p A Address Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Declares that Electronic device E720 conforms to the essential...

Page 15: ...differential thermal breaker with adequate tripping threshold Connect the earth lead to the appropriate terminal Always separate power cables from control and safety cables push button receiver photoc...

Page 16: ...DESCRIPTION 1 OPEN A Device with N O contact that causes total opening of the gate 2 6 GND Accessory power supply negative 3 OPEN B CLOSE SAFE Device with N O contact that causes partial opening of t...

Page 17: ...hotocells it is advisable to select the type of operation on the basis of the area of move ment that they need to protect Safety devices during closing operate only during the automated system closing...

Page 18: ...ient Tab 2 Description of BUS 2EASY led Ensure that there are not two or more pho tocell pairs with the same address If no BUS 2EASY accessory is used leave the BUS 2EASY connector J12 fig 1 free Tab...

Page 19: ...E SAFE SAFE Fig 6 Connection of a pair of closing photocells and a pair of opening photocells Fig 9 SAFE SAFE Connection of a pair of closing photocells a pair of open ing photocells and a pair of ope...

Page 20: ...e name of the next function etc When you reach the last function press push button F to exit the program and store the parameters The display shows again the status of the automated system 1st LEVEL P...

Page 21: ...e total gate travel Adjustable from 5 with speed 5 10 with speed between 5 and 8 15 with speed 8 to 99 in 1 steps 5 10 15 minimum slowing 99 maximum slowing 20 rc SLOWING DURING CLOSING Adjusts the sl...

Page 22: ...ELLS Activate the function if you want the closing photocells to lock movement and reverse it on disengagement Normally operation of the closing photocells immediately puts the gate into reverse when...

Page 23: ...OSED 07 gate in MOTION 08 gate OPENING 09 gate CLOSING 10 ACTIVE safety 11 timed output that can be activated by second radio channel see next function 12 output that can be activated by second radio...

Page 24: ...return to gate status display 00 CLOSED 07 FAIL SAFE in progress 01 OPEN 08 BUS 2EASY device check in progress 02 Stop then OPEN 09 Preflashing then OPEN 03 Stop then CLOSE 10 Preflashing then CLOSE...

Page 25: ...utton twice in quick 1 succession The automated system will carry out an 2 opening control Ensure the automated device is free of any obstacle by people 3 or things To enable other radiocontrols with...

Page 26: ...Normally Closed contact and the corresponding leds must therefore be ON where the automated system is in stand by they will go off when the connected device is engaged The inputs OPEN A OPEN B CLOSE...

Page 27: ...oon as the led for the FCA limit switch on the board goes off secure with the appropriate screws 4 Move the gate to closing position manually leaving 1 5 8 in from the limit switch me chanical stop 5...

Page 28: ...when it reaches the limit switch If the limit switch reached is the opening switch with the SQUARE the device stores that point as the opening stop conversely if the limit switch is the closing switc...

Page 29: ...se inputs are shown in brackets The CLOSE can be activated at the OPEN B input from the 2nd programming level LOGIC E PULSES STATUS OF AUTOMATED SYSTEM OPEN A OPEN B CLOSE STOP FSW OP FSW CL FSW CL OP...

Page 30: ...e opens the gate partially time B no effect no effect OPEN inhibited no effect OPEN inhibited no effect no effect OPEN inhibited DURING OPENING reverses to closing 1 reverses to closing 1 recloses the...

Page 31: ...hibited no effect OPEN inhibited no effect CLOSE inhibited no effect OPEN CLOSE inhibited LOGIC C COMMANDS MAINTAINED PULSES STATUS OFAUTOMATED SYSTEM OPEN A CLOSE STOP FSW OP FSW CL FSW CL OP CLOSED...

Page 32: ...liegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorliege...

Reviews: