7 OPERATIONAL START-UP
7.1 CHECKING THE LEDS
After making all the connections and powering the board, check the status of the leds against the status of the inputs
in the following table (in Fig. 6, the condition where the automated system is closed in stand-by).
These LEDs indicate the status of the board inputs and are of considerable importance to automated system move-
ment:
Note that:
L
ED ON
= contact closed
L
ED OFF
= contact open
< BUS
2EASY
F
< OPEN A
< GND
< OPEN B / CLOSE
/ SAFE
< STOP
/ SAFE
< FSW OP
< GND
< FSW CL
< +24
RADIO XF
-
+
SETUP
USB
OUT
- +
Fig. 13
The inputs STOP, FSW CL, FSW OP are
safety inputs with a N.C. (Normally Closed)
contact and the corresponding leds must
therefore be ON; where the automated
system is in stand-by, they will go off when
the connected device is engaged.
The inputs OPEN A, OPEN B/CLOSE are inputs
with a N.O. (Normally Open) contact and
the corresponding leds must therefore be
OFF; where the automated system is in
stand-by, they will come on when the con-
nected device is engaged.
Leds FCA and FCC represent the N.C. contacts of the limit
switch built into the board that open when engaged and
turn off the associated led:
ERROR led flashing indicates alarm in
progress (situation does not impair gate
operation)
ERROR led on with a fixed light indicates
an error in progress (situation that locks
operation until the cause of the error has
been removed)
Tab. 3 - Description of POWER led
Automated system
CLOSED
FCA
FCC
FCC engaged
Automated system
OPEN
FCA
FCA engaged
FCC