6.3
Temporary Safety Jumpers
For the highest level of safety, the Estate Swing systems are set up with Normally Closed safety
terminals. This means that in order for the gate opener to move these terminals must be closed
either through a safety device (recommended) or with jumpers. Temporary safety jumpers are
provided in the control box hardware bag for jumping these terminals to common (COM) during
the set-up process.
It is recommended not to use any accessories until setup and programming are complete.
NOTE: If not using safety devices the temporary safety jumper must remain in. In order for
the gate operator to move, all three safety terminal lights (STOP, FSW CL, FSW OP) must
be lit.
NOTE: The lights will not come on until the power is applied ot the board in the next step,
but the connections should be made prier to that.