background image

E721 

532014 - Rev.E

ENGLISH

LCD

SIGNALLING AND PROGRAMMING DISPLAY

SW1

PROGRAMMING PUSH-BUTTON "

F

".

SW2

PROGRAMMING PUSH-BUTTON "

-

".

SW3

PROGRAMMING PUSH-BUTTON "

+

".

SW4

SETUP

” PUSH-BUTTON 

LEDs

INPUTS STATUS CONTROL LED

J1

MAIN POWER SUPPLY CONNECTOR

J2

TRANSFORMER PRIMARY WINDING CONNECTOR

J3

TRANSFORMER SECONDARY WINDING CONNECTOR

J4

EMERGENCY BATTERY CONNECTOR (ACCESSORY)

J5

MOTOR CONNECTOR

J6

FLASHING LAMP CONNECTOR 

(24 V= - 15W)

J9

MOTOR LOCK AND MOTOR RELEASE
CONTACT CONNECTOR

J10

OUT OUTPUT CONNECTOR

J11

USB CONNECTOR FOR PC CONNECTION

J12

BUS-2EASY DEVICE CONNECTION CONNECTOR

J13

INPUT CONNECTOR IN CONNECTOR BLOCK

J14

RADIO RECEIVER MODULE CONNECTOR FOR OMNIDEC

LCD1

SIGNALLING AND PROGRAMMING DISPLAY

F1

PROTECTION FUSE 

INPUT

No

DESCRIPTION

1

OPEN A

Device with 

N.O

. contact 

that causes total opening 

of the gate

2-6

GND

Accessory power 

supply negative 

3

(1)

OPEN B 

(DEFAULT)

Device with 

N.O.

 contact 

that causes partial opening 

of the gate

CLOSE

Device with

 

N.O.

 contact 

that closes the gate 

SAFE

Device with

 N.C.

 contact 

that causes the immediate 

and complete reversal of 

the gate

4

(1)

STOP

(DEFAULT)

Device with 

N.C

. contact 

that halts the gate

SAFE

Device with

 N.C.

 contact 

that causes the immediate 

and complete reversal of 

the gate

5

FSW OP

Device with 

N.C

 contact 

that reverses the motion 

during gate opening

7

FSW CL

Device with 

N.C

 contact 

that reverses the motion 

during gate closing

8

+24 V=

Accessory power supply 

positive

Power supply

230 V VERSION  : 230 V~ 50 Hz

115V VERSION    :  115 V~ 60 Hz

Power consumption
from mains stand-by

10 W

Motor max. load

10A

Accessory
power supply

24 V=

Accessory
max. current

 24 V= max. 500 mA

BUS-2EASY max. 500 mA

Environmental
temperature

(-20 - +55) °C

Flashing lamp 
load

24 V= - 15 W 

Output load

24 V= - 100 mA

 (2)

Protection
fuses

F1 = T1A - 250V~

Function 
logics

Semiautomatic, Semiautomatic “step“, 

Automatic, Automatic “step”, Auto-

matic with timer function, Automatic 

Safety devices, Automatic Safety devices 

“step“, Automatic with reverse on pause, 

Semiautomatic “b”, Mixed logic “bC”, 

Dead-man.

Work time

Programmable (from 0 to 10 min.)

Pause time 
OPEN A / OPEN B

Programmable (from 0 to 10 min.)

Motor power

Adjustable over 50 levels

Opening-closing 
motor speed

Adjustable over 10 levels

Connector Inputs/
Outputs

Power supply, Battery, Motor, Module 

XF433/868, 

Motor lock electric release bat-

teries, Motor Lock, 

USB

Inputs/Outputs in 
terminal block

BUS-2EASY, OPEN A, OPEN B/CLOSE/SAFE, 

STOP/SAFE, GND, Opening and closing 

photocells, +24 V=, Mains power supply, 

Flasher, Electric release 

motor lock, OUT

Programming

1

st

 and 2

nd

 level with 3 keys (+, -, F) and 

display.

3  TECHNICAL SPECIFICATIONS

2.1  COMPONENT DESCRIPTION

2.2  DESCRIPTION OF TERMINAL BLOCK J13

 (2) The output load must be considered 

as already included in the max. current 

available for the accessories

 

(1) 

The uses of inputs 3 and 4 can be set by 

configuring the corresponding parameters 

at programming level 2 (parameters 

Ob

 

and 

SP

). For the exact description on how 

to operate the automated system with the 

chosen logics, please refer to the tables 

featured at the end of this manual (Par. 

10 - OPERATION LOGICS. As for the wiring 

required using these SAFE configured 

inputs, please refer to the diagrams shown 

in Fig.13 and Fig. 14

Summary of Contents for E721

Page 1: ...B GND OPEN B CLOSE STOP FSW OP GND FSW CL 24 F C C M A I N P E N L B A T T E R Y M O T O R L A M P L O C K L O C K L O C K P R I M T R A N S F S E C T R A N S F F C A R A D I O 1 R A D I O 2 E R R O R...

Page 2: ...testing in a typical standard configuration all products built by FAAC S p A Bologna 01 12 2011 CEO A Marcellan 1 WARNINGS 2 2 LAYOUT AND COMPONENTS 2 2 1 COMPONENT DESCRIPTION 3 2 2 DESCRIPTION OF T...

Page 3: ...ll upstream of the system a differential thermal breaker with adequate tripping threshold Connect the earth lead to the appropriate terminal Always separate power cables from control and safety cables...

Page 4: ...15 V 60 Hz Power consumption from mains stand by 10 W Motor max load 10A Accessory power supply 24 V Accessory max current 24 V max 500 mA BUS 2EASY max 500 mA Environmental temperature 20 55 C Flashi...

Page 5: ...7 7 7 7 7 7 7 7 7 7 7 7 7 7 72 2 2 230 V 115 V ENGLISH A Photocells that operate during CLOSING B Photocells that operate during OPENING C Photocells that operate during OPENING and CLOSING MOTOR RELE...

Page 6: ...par 4 1 1 2 Cut off power to the board 3 Connect both cables of the BUS 2EASY accessories to the red terminal block J12 polarity irrelevant 4 Power the board 5 Quickly press the SETUP push button SW4...

Page 7: ...fety device deactivated Connection of 1 pair of closing photocells with FAIL SAFE safety device activated Other safety devices Set in second level of programming o1 01 Other safety devices 4 2 TRADITI...

Page 8: ...setting 2nd level o1 00 FAIL SAFE DISABLED 2nd level SP 01 INPUT 4 SAFETY EDGE SAFETY By setting 2nd level o1 00 FAIL SAFE DISABLED 2nd level Ob 02 INPUT 3 SAFETY EDGE SAFETY Other safety devices 4 3...

Page 9: ...n press push button F to exit the program and store the parameters The display shows again the status of the automated system 1st LEVEL PROGRAMMING Display Function Default 1 dF DEFAULT 1 Configures t...

Page 10: ...peed 1 0 maximum speed When the speed value has been changed it is advisable to perform a new SETUP see par 7 3 08 ro SLOWING DURING OPENING Adjusts the slowing space as a percentage of the total gate...

Page 11: ...you want the closing photocells to lock movement and reverse it on disengagement Normally operation of the closing photocells immediately puts the gate into reverse when this function is off Y revers...

Page 12: ...next function 12 output that can be activated by second radio channel step function 00 t1 TIMING OF OUT 1 only if option 03 or 11 is selected at the previous step Can be used to adjust timing of outpu...

Page 13: ...EN 03 Stop then CLOSE 04 In PAUSE 05 During opening stage 06 During closing stage 07 FAIL SAFE in progress 08 BUS 2EASY device check in progress 09 Preflashing then OPEN 10 Preflashing then CLOSE 11 O...

Page 14: ...ee of any obstacle by people or things 6 3 STORING LC RC RADIOCONTROLS It is possible to store a maximum of 256 codes divided between OPEN A and OPEN B CLOSE Use the LC RC remote controls only with a...

Page 15: ...the cause of the error has been removed Fixed ON Mains powered Flashing Battery powered Off Board off Tab 3 Description of POWER LED 7 2 BATTERY OPERATION ATTENTION To optimise energy consumption and...

Page 16: ...e LED for the FCA limit switch on the board goes off secure with the appropriate screws 4 Move the gate to closing position manually leaving 40 mm from the limit switch me chanical stop 5 Slide the ma...

Page 17: ...erminal board POLE 1 POLE 2 see Fig 19 When a unit is configured as a SLAVE this will force the values of some programming parameters no longer displayed in the menu LO PA Pb Ph Op By placing the boar...

Page 18: ...encoder will cause the motion to reverse At the next motion in the same direction an obstacle in the same position will cause the motor to stop It is essential to correctly configure this parameter to...

Page 19: ...OP FSW OP FSW CL FSW CL OP CLOSED opens the gate opens the gate partially no effect no effect OPEN inhibited no effect OPEN inhibited no effect no effect OPEN inhibited DURING OPENING locks operation...

Page 20: ...ses reclosesthegate noeffect OPEN CLOSEinhibited noeffect OPENinhibited noeffect CLOSEinhibited noeffect OPEN CLOSEinhibited LOGIC S PULSES STATUS OF AUTOMATED SYSTEM OPEN A OPEN B CLOSE STOP FSW OP F...

Page 21: ...ED opensthegate closesthegate noeffect OPEN CLOSEinhibited noeffect OPENinhibited noeffect CLOSEinhibited noeffect OPEN CLOSEinhibited LOGIC B PULSES STATUS OF AUTOMATED SYSTEM OPEN A CLOSE STOP FSW O...

Page 22: ...79 6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 35...

Reviews: